Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: ESF50/20

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

200 GPM Horizontal Fire Pump

,

143 PSI Horizontal Fire Pump

,

NFPA 20 Horizontal Fire Pump

Inletsize:
100-200 M
Frequency:
50Hz / 60Hz
Productname:
Fire Sprinkler Pump
Pumptype:
Centrifugal Pump
Material:
Cast Iron / Stainless Steel
Application:
Fire Protection Systems
Phase:
3 Phase
Inletsize:
100-200 M
Frequency:
50Hz / 60Hz
Productname:
Fire Sprinkler Pump
Pumptype:
Centrifugal Pump
Material:
Cast Iron / Stainless Steel
Application:
Fire Protection Systems
Phase:
3 Phase
ESF50/20 Horizontal End Suction Fire Pump 200 GPM @ 56–143 PSI Designed For NFPA 20 Fire Protection Systems
ESF50/20 Horizontal End Suction Fire Pump 200 GPM @ 56–143 PSI Designed For NFPA 20 Fire Protection Systems
FM APPROVED  |  NFPA 20 COMPLIANT  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE ESF50/20 is an FM Approved horizontal end suction fire pump delivering 200 GPM at 56–143 PSI for NFPA 20 fire protection systems. The 200 GPM class suits hotels, mid-size commercial buildings, and institutional facilities across Kenya and wider African markets.

The overhung-impeller, back pull-out construction keeps the footprint small and the installation straightforward — an economical alternative to horizontal split case pumps where the duty fits. The ESF50/20 is available with either an electric motor (ODP or TEFC enclosure, 15–50 HP) or a diesel engine driver (39–86 HP), so the same certified hydraulic package can be matched to reliable-grid sites or to weak-grid African locations where diesel drive is preferred for independence from the mains supply.

Manufactured to NFPA 20 requirements with fm approved, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

Key Specifications

Product Type: Horizontal End Suction Fire Pump
Model: ESF50/20
Certification: FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Rated Flow: 200 GPM
Pressure Range: 56-143 PSI
Driver Type: Electric Motor (ODP / TEFC) or Diesel Engine
Pump Speed: 2980 RPM (50 Hz) / 3550 RPM (60 Hz)
Pump Type: Horizontal End Suction, Back Pull-Out
Application: Commercial / Industrial / Infrastructure

Pump Range Overview
Parameter Specification
Rated Flow 200 GPM
Pressure Range 56 – 143 PSI
Head Range 37 – 101 m
Pump Speed 2980 RPM (50 Hz) / 3550 RPM (60 Hz)
Max Shaft Power 58 HP / 43.3 kW
Driver ODP / TEFC Electric Motor (15–50 HP) or Diesel Engine (39–86 HP)
Certifications FM Approved
Example Duty Point Configuration
Parameter Value
Pump Model ESF50/20
Rated Flow 200 GPM
Rated Pressure 100 PSI
Max Shaft Power 37 HP / 27.6 kW
Pump Speed 2980 RPM (50 Hz)
Motor Model F-TXC 324TS40U2B (40 HP TEFC)
Controller Tornatech
Key Features
  • FM Approved certification
  • Designed and tested per NFPA 20 requirements
  • 200 GPM duty point with selectable pressure ratings from 56 to 143 PSI
  • Choice of electric motor drive (ODP / TEFC, 15–50 HP) or diesel engine drive — matched to site power conditions
  • Compact end suction layout — economical footprint versus split case equivalents
  • Back pull-out construction — rotating assembly serviced without disturbing suction and discharge piping
  • SS420 stainless steel shaft with SKF bearings — corrosion-resistant, reliable, globally sourced spares
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
Applications

Hotels & Hospitality

Sprinkler and standpipe systems for hotels and resorts — a core 200 GPM duty across Kenya and East Africa.

Mid-Size Commercial Buildings

Offices, retail centers, and mixed-use developments with moderate hazard classifications.

Institutional Facilities

Schools, clinics, and university campuses protected per NFPA 20.

Weak-Grid & Remote Sites

Diesel-driven configuration maintains full fire protection capability independent of the mains supply — suited to safari lodges, resorts, and regions with unstable grid power.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required engine power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Shaft SS420
Seal Gland Packing
Wear Ring Brass
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

ESF Design & Maintenance Features
Horizontal End Suction Fire Pump — Design Advantages:
Compact footprint — overhung-impeller end suction layout needs less floor space than an equivalent split case pump, fitting small plant rooms and budget-conscious projects
Back pull-out construction — the rotating assembly (impeller, shaft, gland packing, wear ring) is removed from the back of the pump without disturbing the suction and discharge piping, minimizing maintenance downtime
SS420 stainless steel shaft — high strength with good corrosion resistance at the sealing area
Gland packing seal — robust and field-serviceable, standard for fire pump duty
SKF bearings — internationally sourced, spares available worldwide
Brass wear ring — replaceable running clearance protects the casing and impeller
Dual driver options — ODP or TEFC electric motor (15–50 HP) for reliable-grid sites, or diesel engine (39–86 HP) for weak-grid and remote locations
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a horizontal end suction fire pump, and why choose the ESF50/20?

A horizontal end suction fire pump takes suction on the horizontal axis through the casing eye and discharges vertically from the top of the casing. Compared with a horizontal split case pump, the end suction layout is simpler, more compact, and more economical — well suited to smaller fire protection duties. The NMFIRE ESF50/20 delivers 200 GPM at 56–143 PSI in this format, FM Approved per NFPA 20, with a back pull-out design that allows the rotating assembly to be serviced without disturbing the piping.

What is the difference between end suction, horizontal split case, and vertical inline fire pumps?

Horizontal split case pumps split the casing horizontally, so internal parts are serviced by removing the top half without disturbing piping; they are typically used for medium to high flow duties. End suction pumps have a single-piece casing with suction on the axis and discharge on top — the most compact and economical layout for small to medium duties such as 50–750 GPM, and available from NMFIRE in high-flow ratings up to 2500 GPM. Vertical inline pumps mount the motor above the pump with both nozzles on the same vertical centerline, minimizing footprint in very tight plant rooms. All three types are available from NMFIRE with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.

What is the flow and pressure range of the ESF50/20?

The ESF50/20 is rated at 200 GPM, with selectable pressure ratings from 56 to 143 PSI (head 37–101 m) at 2980 RPM (50 Hz) / 3550 RPM (60 Hz). Maximum shaft power is 37 HP / 27.6 kW at the 100 PSI duty point. Each duty point is driven by a matched ODP or TEFC electric motor from 15 to 50 HP, or by a diesel engine (39 to 86 HP) where electric supply is unreliable. The full selection table and performance curves are available on request.

Should I choose an electric or diesel driven end suction fire pump?

The choice depends on the reliability of the site power supply. Where the mains supply is dependable, an electric driven fire pump (ODP or TEFC enclosure) offers lower installed cost, simpler maintenance, and no fuel storage requirements. Where the grid is unstable or unavailable — common across many African project locations — a diesel driven fire pump keeps the fire protection system fully independent of mains power per NFPA 20. The ESF50/20 is certified with both driver options, so the same hydraulic package can be configured either way for your project.

How do I size a fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure at the topmost outlet, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off (zero flow), pressure must not exceed 140% of rated. NMFIRE engineering can verify the duty point against the ESF50/20 selection table and issue a project-specific performance curve for consultant approval.

What package options are available for the ESF50/20?

The ESF50/20 pump unit itself comprises the end suction pump and its electric motor or diesel engine driver. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL Listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

What applications suit a 200 GPM end suction fire pump?

A 200 GPM fire pump is a typical rating for hotels and resorts, mid-size office and retail buildings, schools, and clinics. The ESF50/20's 56–143 PSI range (50 Hz and 60 Hz options) covers standard standpipe and sprinkler demands, and its diesel-driven option suits safari lodges, resorts, and other locations across Kenya and East Africa where grid supply is unreliable. For smaller or larger duties, NMFIRE offers a full range from 50 to 2500 GPM.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The ESF50/20 horizontal end suction model is FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

Technical Guides & Resources
  • NFPA 20 Fire Pump Selection Guide — How to select the right pump for your project
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • End Suction vs Split Case Fire Pump — Choosing the right configuration for your duty
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • Fire Pump Package Components — Complete guide to pump, controller, jockey pump, relief valve
  • Skid-Mounted & Containerized Fire Pump Stations — Pre-assembled delivery options

NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.