logo
Wuhan Spico Machinery & Electronics Co., Ltd.
products
products
Home > products > > SCF125-80-350  UL/FM Horizontal Split Case Fire Pump  500–1000 GPM, 750 GPM @ 195 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

SCF125-80-350  UL/FM Horizontal Split Case Fire Pump  500–1000 GPM, 750 GPM @ 195 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: SCF125-80-350

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

SCF125-80-350 UL/FM Split Case Fire Pump

,

SCF125-80-350 Split Case Fire Pump

,

SCF125-80-350 1000GPM Split Case Fire Pump

Installationtype:
Horizontal
Powersource:
Electric / Diesel Engine
Pumptype:
Centrifugal
Productname:
Fire Sprinkler Pump
Controlpanel:
Automatic / Manual
Flowrate:
500-2000 L/min
Installationtype:
Horizontal
Powersource:
Electric / Diesel Engine
Pumptype:
Centrifugal
Productname:
Fire Sprinkler Pump
Controlpanel:
Automatic / Manual
Flowrate:
500-2000 L/min
SCF125-80-350  UL/FM Horizontal Split Case Fire Pump  500–1000 GPM, 750 GPM @ 195 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive
SCF125-80-350  UL/FM Horizontal Split Case Fire Pump  500–1000 GPM, 750 GPM @ 195 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive
UL LISTED  |  FM APPROVED  |  NFPA 20 COMPLIANT  |  50Hz / 60Hz  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE SCF125-80-350 is a UL Listed and FM Approved horizontal split case fire pump covering 500–1000 GPM with pressure from 99 to 308 PSI for NFPA 20 fire protection systems. At the 750 GPM duty point it delivers 164–295 PSI on 50Hz supply and up to 308 PSI on 60Hz supply, making it a versatile high-flow high-pressure 5-inch suction split case fire pump for mining, power generation, and heavy industrial facilities across Africa and other export markets.

The pump is rated for triple-speed operation: 2950 RPM at 50Hz — matching the power grids of Africa, the Middle East, Asia, and Europe; 3550 RPM at 60Hz for the Americas; and 2200 RPM diesel-only for reduced-speed UL-rated duties that extend engine life and reduce noise. Driver options include ODP or TEFC electric motors (100–250 HP) and six diesel engine models (NM4 and NM6 series, 109–335 HP) for sites with unreliable or no mains power, giving the widest diesel selection in the SCF range.

The horizontally split casing opens for service without disturbing the suction and discharge piping — impeller, wear rings, and gland packing can be inspected and replaced with the pump in place. The robust between-bearings shaft support delivers stable hydraulic performance across the full 500–1000 GPM range. Manufactured to NFPA 20 requirements with UL Listing and FM Approval, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

Key Specifications

Product Type: Horizontal Split Case Fire Pump
Model: SCF125-80-350
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 500-1000 GPM
Pressure Range: 99-308 PSI (750 GPM duty: 164-308 PSI)
Pump Speed: 2200 RPM (Diesel UL) / 2950 RPM (50Hz) / 3550 RPM (60Hz)
Driver Type: ODP / TEFC Electric Motor (100-250 HP) or Diesel Engine (109-335 HP)
Pump Type: Horizontal Split Case
Application: Mining / Power Plant / Industrial / Oil & Gas / Infrastructure

SCF125-80-350  UL/FM Horizontal Split Case Fire Pump  500–1000 GPM, 750 GPM @ 195 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Pump Range Overview
Parameter Specification
Rated Flow 500 / 750 / 1000 GPM
Pressure Range 99 – 308 PSI
Head Range 70 – 217 m
Pump Speed 2200 / 2950 RPM (50Hz) / 3550 RPM (60Hz)
Driver Options ODP / TEFC Motor 100 – 250 HP; Diesel Engine 109 – 335 HP
Certifications UL Listed / FM Approved
Suction / Discharge DN125 (5″) / DN80 (3″)
Example Duty Point Configuration
Parameter Value
Pump Model SCF125-80-350
Rated Flow 750 GPM
Rated Pressure 195 PSI
Pump Speed 2950 RPM (50Hz)
Max Shaft Power 134 HP / 100 kW
Motor Option F-TXC 444TS125U2B (125 HP TEFC)
Diesel Option NM6-110B (153 HP)
Controller Tornatech
Key Features
  • UL Listed and FM Approved dual certification
  • Designed and tested per NFPA 20 requirements
  • Triple-speed operation — 2200 RPM (diesel-only UL), 2950 RPM (50Hz), and 3550 RPM (60Hz) from one pump model
  • 500–1000 GPM wide flow coverage with pressure up to 308 PSI — the widest operating envelope in the SCF range
  • Six diesel engine options (NM4/NM6 series, 109–335 HP) — the most diesel choices in the SCF range
  • Electric motor drive (ODP / TEFC, 100–250 HP) or diesel engine drive (109–335 HP)
  • 1000 GPM extension capability at 50Hz — covers large industrial systems from a single pump model
  • Split case construction — internal parts serviceable without disturbing piping
  • Replaceable bronze wear rings maintain internal clearances and hydraulic efficiency
  • Diesel engine altitude and temperature derating calculated per site conditions
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
Applications

Mining & Mineral Processing

750 GPM at 195 PSI is a proven duty for mine-site fire protection — the SCF125-80-350 is a proven choice for copper, gold, and cobalt mining operations in Uganda and across African markets on 50Hz power grids, with diesel backup for remote sites.

Power Plants & Energy Facilities

High flow at high pressure (up to 308 PSI) covers turbine hall sprinkler, hydrant, and water spray systems for thermal and renewable power stations with large protected areas.

Oil & Gas / Petrochemical

308 PSI high-pressure capability and 1000 GPM extension suit refinery and terminal fire water systems where NFPA 20 demands high-residual-pressure deluge and monitor coverage.

Sites Without Reliable Mains Power

Six diesel engine options keep the fire pump running through grid outages — the most diesel selections in the SCF range, including a 2200 RPM reduced-speed engine for extended life and quieter operation.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required motor power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Shaft AISI 4340
Shaft Sleeve SS304
Seal Gland Packing
Wear Ring Bronze
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

Speed & Driver Options
One Pump Model — Three Speeds:
50Hz operation at 2950 RPM — matches power grids in Africa, the Middle East, Asia, and Europe; the standard configuration for Ugandan, Nigerian, Ghanaian, and other African projects
60Hz operation at 3550 RPM — matches power grids in the Americas and other 60Hz territories; extends to 308 PSI maximum pressure
2200 RPM diesel-only (UL rated) — reduced-speed operation for 500 GPM duties at 99–161 PSI; extends engine life, reduces noise, and lowers fuel consumption
Same UL/FM certified hydraulics — the selection table covers all three speeds, with driver size matched to each duty point
Electric Motor Options (ODP vs TEFC)

The SCF125-80-350 electric drive is available with motor size matched to each duty point from 100 to 250 HP:

  • ODP (Open Drip Proof) — economical enclosure for clean, dry, well-ventilated indoor pump rooms
  • TEFC (Totally Enclosed Fan Cooled) — sealed enclosure for dusty, humid, hot, or outdoor-adjacent environments; the common choice for African project sites
Diesel Engine Drive (Six Options)

The SCF125-80-350 offers the most diesel engine options in the SCF range — six models spanning NM4 and NM6 series, rated 109–335 HP, all at 50Hz (2950/2200 RPM), giving maximum flexibility to match the exact duty point and site conditions:

  • NM4-104B — 109 HP at 2200 RPM, UL-rated reduced-speed engine for 500 GPM low-pressure duties (99–161 PSI); longest engine life and lowest noise
  • NM4-108B — 117–121 HP at 2950 RPM, for 750 GPM low-pressure 50Hz duties (164–175 PSI)
  • NM6-110B — 148–153 HP at 2950 RPM, the standard 50Hz diesel selection for 750 GPM mid-range duties (180–215 PSI)
  • NM6-110E — 192 HP at 2900 RPM, for 750 GPM higher-pressure 50Hz duties (210–245 PSI)
  • NM6-110D — 239–268 HP at 2900 RPM, for 750 GPM high-pressure 50Hz duties (245–295 PSI)
  • NM6-108E — 335 HP at 2950 RPM, for the highest-pressure 50Hz duties at 750 GPM (275–295 PSI) and 1000 GPM extension

Diesel packages include engine-driven cooling, starting batteries, and engine controller matched per NFPA 20. Note: diesel drive is available at 50Hz (2950/2200 RPM) duty points only; 60Hz (3550 RPM) duty points are served by electric motor drive.

Altitude & Temperature Derating
Diesel Engine Derating per NFPA 20:
Engine nameplate power must be derated for site conditions:
• Approximately 3% power reduction per 300m (1000 ft) above sea level
• Approximately 1% power reduction per 5.5°C (10°F) above 25°C (77°F)

With six engine options spanning 109–335 HP, the SCF125-80-350 has the greatest flexibility in the SCF range to absorb altitude and temperature derating — if the standard engine derates below the required shaft power at site conditions, the next engine model up is available without changing the pump. For high-altitude mining sites in Uganda, DRC, and other African highland projects, this means the pump can be matched to the derated engine output rather than oversizing at sea level. NMFIRE engineering calculates derating factors based on actual project site conditions to ensure the engine has sufficient standby power at the specified flow and pressure duty point.
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a split case fire pump, and how does it work?

A horizontal split case fire pump has a casing split along the shaft centerline. Lifting the upper casing half exposes the impeller, wear rings, and shaft for inspection or parts replacement — without disconnecting the suction or discharge piping. The impeller is supported between two bearings, giving smooth, stable operation across a wide flow range. The NMFIRE SCF125-80-350 applies this design to the 500–1000 GPM range with UL Listing and FM Approval per NFPA 20.

What is the difference between UL Listed and FM Approved fire pumps?

UL (Underwriters Laboratories) Listing and FM (FM Approvals) certification are two independent third-party certifications verifying that a fire pump meets the applicable standards (such as UL 448 and FM 1311). Both are widely accepted by fire protection consultants, insurers, and authorities having jurisdiction in export markets. Many projects specify either one; some require both. The SCF125-80-350 carries both UL Listing and FM Approval, giving maximum flexibility for consultant approval and insurance acceptance on international projects.

What is the flow and pressure range of the SCF125-80-350?

The SCF125-80-350 covers rated flows of 500, 750, and 1000 GPM, with pressure ratings from 99 to 308 PSI (head 70–217 m). At the 750 GPM duty point, 50Hz operation (2950 RPM) delivers 164–295 PSI while 60Hz operation (3550 RPM) reaches 251–308 PSI. The 1000 GPM extension is available at 50Hz only. Driver options span ODP/TEFC electric motors from 100 to 250 HP and six diesel engines from 109 to 335 HP. The full selection table and performance curves for each flow/pressure/speed combination are available on request.

50Hz or 60Hz — which fire pump frequency do I need?

Match the pump to your site power supply. Most of Africa (including Uganda, Nigeria, and Ghana), the Middle East, Asia, and Europe use 50Hz grids, where the SCF125-80-350 runs at 2950 RPM. The Americas and a few other territories use 60Hz, where the pump runs at 3550 RPM and can extend to 308 PSI. The same UL/FM certified pump model serves both — only the rated speed, pressure envelope, and driver selection differ. If your site has unreliable or no mains power, a diesel engine drive (rated at 2950 or 2200 RPM, 50Hz duty points only) provides an independent backup per NFPA 20.

How do I size a split case fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off, pressure must not exceed 140% of rated. NMFIRE engineering can verify your duty point against the SCF125-80-350 selection table and issue a project-specific performance curve for consultant approval.

Split case vs end suction vs vertical inline fire pump — which should I choose?

Horizontal split case pumps are the most common fire pump type: easy to service in place, and suitable for medium to high flow duties (the SCF125-80-350 covers 500–1000 GPM with pressure up to 308 PSI). End suction pumps offer a simple, economical layout for lower duties. Vertical inline pumps have the most compact footprint for space-limited plant rooms and retrofits. All three types are available from NMFIRE with UL Listed and FM Approved certification per NFPA 20. Selection depends on project flow, available space, and maintenance strategy.

Why does the SCF125-80-350 offer six diesel engine options?

The SCF125-80-350 has the most diesel engine options in the SCF range because its duty points span a very wide pressure band (99–308 PSI) at three flow rates and three speeds, each requiring different shaft power. Rather than oversizing a single engine for all duties — which wastes fuel and cost — NMFIRE matches the engine to the exact duty point: NM4-104B (109 HP at 2200 RPM) for reduced-speed low-pressure duties, NM4-108B (117–121 HP) for low-pressure 50Hz, NM6-110B (148–153 HP) for mid-range, NM6-110E (192 HP) for higher-pressure, NM6-110D (239–268 HP) for high-pressure, and NM6-108E (335 HP) for the highest-pressure 50Hz duties and 1000 GPM extension. This also gives margin to absorb altitude and temperature derating — if the standard engine derates below the required power at site conditions, the next model up is available without changing the pump.

What is the 2200 RPM diesel-only speed, and when should I use it?

The 2200 RPM speed is a diesel-engine-only, UL-rated operating mode available for 500 GPM duty points at 99–161 PSI. Running the engine at reduced speed (2200 RPM instead of 2950 RPM) extends engine life, reduces mechanical noise, and lowers fuel consumption — important for sites with continuous standby operation or noise-sensitive environments such as residential-adjacent pump rooms. The NM4-104B engine (109 HP) is paired to this speed. Note that 2200 RPM duties are UL-rated only (not FM); FM-rated duties require 2950 or 3550 RPM operation.

Can the SCF125-80-350 handle 1000 GPM large industrial systems?

Yes. The SCF125-80-350 extends to 1000 GPM at 50Hz (2950 RPM), with pressure from 164 to 295 PSI and shaft power up to 257 HP. This makes it suitable for large industrial fire water systems — power plants, refineries, mining complexes — that exceed the 750 GPM rating without needing a larger pump model. At 60Hz (3550 RPM), the maximum rated flow is 750 GPM. For projects requiring 1000 GPM at 60Hz, NMFIRE offers larger SCF series models. The 1000 GPM duty point is available with both electric motor and diesel engine drive at 50Hz.

What applications suit a 750 GPM split case fire pump?

A 750 GPM fire pump at 164–295 PSI is a standard duty for high-hazard industrial occupancies: mining and mineral processing facilities (a frequent requirement in Uganda and across Africa), power generation plants, oil and gas terminals, cement factories, and large manufacturing complexes. The high-pressure characteristic of the SCF125-80-350 matches projects where deluge systems, monitors, and standpipes demand substantial residual pressure at high flow. For even larger systems, the 1000 GPM extension at 50Hz covers the most demanding industrial fire water duties from the same pump model.

What package options are available for the SCF125-80-350?

The SCF125-80-350 pump unit itself comprises the horizontal split case pump and its electric motor or diesel engine. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL/FM listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The SCF125-80-350 horizontal split case model is UL Listed and FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

SCF125-80-350  UL/FM Horizontal Split Case Fire Pump  500–1000 GPM, 750 GPM @ 195 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Technical Guides & Resources
  • NFPA 20 Fire Pump Selection Guide — How to select the right pump for your project
  • 50Hz vs 60Hz Fire Pump Operation — Matching pump speed to your power grid
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • Six Diesel Engine Options — Matching NM4/NM6 engine model to duty point and site conditions
  • 2200 RPM Reduced-Speed Diesel Operation — When and why to choose low-speed diesel drive
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • Split Case Fire Pump Design & Maintenance Guide — Casing access and in-place service
  • Diesel Engine Altitude & Temperature Derating — Sizing engines for site conditions
  • ODP vs TEFC Motor Selection — Matching motor enclosure to site environment
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • High-Pressure Fire Pump Applications — Mining, power plant, and refinery system sizing
  • 1000 GPM Fire Pump Extension — Sizing large industrial fire water systems at 50Hz

NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.

Tags:

Similar Products