logo
Wuhan Spico Machinery & Electronics Co., Ltd.
products
products
Home > products > > SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: SCF100-80-250

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

SCF100-80-250  Split Case Fire Pump

,

 300–500 GPM Split Case Fire Pump

Pressure Range:
91-132 PSI
Suction Size:
4-inch
Head Range:
64-93 M
Discharge Size:
3-inch
Pump Speed:
3550 RPM
Motor Power:
40-60 HP
Flow Range:
300-500 GPM
Pressure Range:
91-132 PSI
Suction Size:
4-inch
Head Range:
64-93 M
Discharge Size:
3-inch
Pump Speed:
3550 RPM
Motor Power:
40-60 HP
Flow Range:
300-500 GPM
SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive
SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive
UL LISTED  |  FM APPROVED  |  NFPA 20 COMPLIANT  |  50Hz / 60Hz  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE SCF100-80-250 is a UL Listed and FM Approved horizontal split case fire pump covering 300–500 GPM with pressure up to 218 PSI for NFPA 20 fire protection systems. At the 400 GPM duty point it delivers 83–149 PSI on 50Hz supply and up to 215 PSI on 60Hz supply, making it a versatile high-pressure 4-inch suction split case fire pump for hotels, high-rise buildings, and industrial projects across Africa and other export markets.

The pump is rated for dual-frequency operation: 2980 RPM at 50Hz — matching the power grids of Africa, the Middle East, Asia, and Europe — and 3550 RPM at 60Hz for the Americas. Driver options include ODP or TEFC electric motors (40–100 HP) and NM4 series diesel engines (39–121 HP) for sites with unreliable or no mains power, so a single pump model serves both electric and diesel fire pump configurations.

The horizontally split casing opens for service without disturbing the suction and discharge piping — impeller, wear rings, and gland packing can be inspected and replaced with the pump in place. The robust between-bearings shaft support delivers stable hydraulic performance across the whole 300–500 GPM range. Manufactured to NFPA 20 requirements with UL Listing and FM Approval, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Key Specifications

Product Type: Horizontal Split Case Fire Pump
Model: SCF100-80-250
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 300-500 GPM
Pressure Range: 78-218 PSI (400 GPM duty: 83-149 PSI @ 50Hz)
Pump Speed: 2980 RPM (50Hz) / 3550 RPM (60Hz)
Driver Type: ODP / TEFC Electric Motor (40-100 HP) or Diesel Engine (39-121 HP)
Pump Type: Horizontal Split Case
Application: Commercial / Industrial / Infrastructure

Pump Range Overview
Parameter Specification
Rated Flow 300 / 400 / 450 / 500 GPM
Pressure Range 78 – 218 PSI
Head Range 55 – 153 m
Pump Speed 2980 RPM (50Hz) / 3550 RPM (60Hz)
Driver Options ODP / TEFC Motor 40 – 100 HP; Diesel Engine 39 – 121 HP
Certifications UL Listed / FM Approved
Suction / Discharge DN100 (4″) / DN80 (3″)
Example Duty Point Configuration
Parameter Value
Pump Model SCF100-80-250
Rated Flow 400 GPM
Rated Pressure 110 PSI
Pump Speed 2980 RPM (50Hz)
Max Shaft Power 48 HP / 36 kW
Motor Option F-TXC 326TS50U2B (50 HP TEFC)
Diesel Option NM4-90 (51 HP)
Controller Tornatech
Key Features
  • UL Listed and FM Approved dual certification
  • Designed and tested per NFPA 20 requirements
  • Dual-frequency operation — 2980 RPM (50Hz) and 3550 RPM (60Hz) from one pump model
  • 400 GPM duty point, pressure up to 218 PSI for high-rise and standpipe systems
  • Electric motor drive (ODP / TEFC, 40–100 HP) or diesel engine drive (NM4 series, 39–121 HP)
  • Split case construction — internal parts serviceable without disturbing piping
  • Diesel engine altitude and temperature derating calculated per site conditions
  • Factory performance tested before shipment
  • Engineering documents available for project submittal

SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Applications

Hotels & Hospitality

Dependable 400 GPM sprinkler and standpipe water supply for hotels and resorts — a core fire protection duty across Kenya and wider African markets on 50Hz power grids.

High-Rise & Commercial Buildings

Pressure capability up to 218 PSI covers standpipe systems in mid- and high-rise offices, residential towers, and shopping malls.

Manufacturing & Warehousing

Reliable fire protection for factories, workshops, logistics centers, and storage facilities with moderate-to-high capacity demand.

Sites Without Reliable Mains Power

NM4 series diesel engine drive keeps the fire pump running through grid outages — a frequent requirement for remote and rural project sites.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required motor power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Shaft AISI 4340
Shaft Sleeve SS304
Seal Gland Packing
Wear Ring Bronze
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

Dual-Frequency Operation & Driver Options
One Pump Model — Both Power Systems:
50Hz operation at 2980 RPM — matches power grids in Africa, the Middle East, Asia, and Europe; the standard configuration for Kenyan, Nigerian, Ghanaian, and other African projects
60Hz operation at 3550 RPM — matches power grids in the Americas and other 60Hz territories
Same UL/FM certified hydraulics — the selection table covers both speeds, with driver size matched to each duty point
Electric Motor Options (ODP vs TEFC)

The SCF100-80-250 electric drive is available with motor size matched to each duty point from 40 to 100 HP:

  • ODP (Open Drip Proof) — economical enclosure for clean, dry, well-ventilated indoor pump rooms
  • TEFC (Totally Enclosed Fan Cooled) — sealed enclosure for dusty, humid, hot, or outdoor-adjacent environments; the common choice for African project sites
Diesel Engine Drive (NM4 Series)

For sites with unreliable mains power or no grid connection, the SCF100-80-250 can be driven by an NM4 series diesel engine rated 39–121 HP at 2950 RPM — the NFPA 20 preferred configuration where a backup power source is required for the fire pump. Diesel packages include engine-driven cooling, starting batteries, and engine controller matched per NFPA 20.

Altitude & Temperature Derating
Diesel Engine Derating per NFPA 20:
Engine nameplate power must be derated for site conditions:
• Approximately 3% power reduction per 300m (1000 ft) above sea level
• Approximately 1% power reduction per 5.5°C (10°F) above 25°C (77°F)

NMFIRE engineering calculates derating factors based on actual project site conditions to ensure the engine has sufficient standby power at the specified flow and pressure duty point.
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


SCF100-80-250  UL/FM Horizontal Split Case Fire Pump  300–500 GPM, 400 GPM @ 110 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a split case fire pump, and how does it work?

A horizontal split case fire pump has a casing split along the shaft centerline. Lifting the upper casing half exposes the impeller, wear rings, and shaft for inspection or parts replacement — without disconnecting the suction or discharge piping. The impeller is supported between two bearings, giving smooth, stable operation across a wide flow range. The NMFIRE SCF100-80-250 applies this design to the 300–500 GPM range with UL Listing and FM Approval per NFPA 20.

What is the difference between UL Listed and FM Approved fire pumps?

UL (Underwriters Laboratories) Listing and FM (FM Approvals) certification are two independent third-party certifications verifying that a fire pump meets the applicable standards (such as UL 448 and FM 1311). Both are widely accepted by fire protection consultants, insurers, and authorities having jurisdiction in export markets. Many projects specify either one; some require both. The SCF100-80-250 carries both UL Listing and FM Approval, giving maximum flexibility for consultant approval and insurance acceptance on international projects.

What is the flow and pressure range of the SCF100-80-250?

The SCF100-80-250 covers rated flows of 300, 400, 450, and 500 GPM, with pressure ratings from 78 to 218 PSI (head 55–153 m). At the 400 GPM duty point, 50Hz operation (2980 RPM) delivers 83–149 PSI while 60Hz operation (3550 RPM) reaches up to 215 PSI. Driver options span ODP/TEFC electric motors from 40 to 100 HP and NM4 series diesel engines from 39 to 121 HP. The full selection table and performance curves for each flow/pressure/speed combination are available on request.

50Hz or 60Hz — which fire pump frequency do I need?

Match the pump to your site power supply. Most of Africa (including Kenya, Nigeria, and Ghana), the Middle East, Asia, and Europe use 50Hz grids, where the SCF100-80-250 runs at 2980 RPM. The Americas and a few other territories use 60Hz, where the pump runs at 3550 RPM. The same UL/FM certified pump model serves both — only the rated speed, pressure envelope, and driver selection differ. If your site has unreliable or no mains power, a diesel engine drive (rated at 2950 RPM) provides an independent backup per NFPA 20.

How do I size a split case fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off, pressure must not exceed 140% of rated. NMFIRE engineering can verify your duty point against the SCF100-80-250 selection table and issue a project-specific performance curve for consultant approval.

Split case vs end suction vs vertical inline fire pump — which should I choose?

Horizontal split case pumps are the most common fire pump type: easy to service in place, and suitable for medium to high flow duties (the SCF100-80-250 covers 300–500 GPM with pressure up to 218 PSI). End suction pumps offer a simple, economical layout for lower duties. Vertical inline pumps have the most compact footprint for space-limited plant rooms and retrofits. All three types are available from NMFIRE with UL Listed and FM Approved certification per NFPA 20. Selection depends on project flow, available space, and maintenance strategy.

Can the SCF100-80-250 be supplied with electric or diesel engine drive?

Yes. The same UL/FM certified pump is available with ODP or TEFC electric motor drive (40–100 HP, 50Hz or 60Hz) or with NM4 series diesel engine drive (39–121 HP at 2950 RPM). Diesel drive is the NFPA 20 preferred choice where a backup power source is required — common on sites with unreliable grids. Engine power is verified per site altitude and ambient temperature per NFPA 20 derating rules, and the diesel package includes engine controller, batteries, and cooling matched to the duty point.

Can the SCF100-80-250 handle high pressure applications up to 218 PSI?

Yes. The SCF100-80-250 is one of the higher-pressure models in the compact 4-inch suction SCF range, reaching 218 PSI at 60Hz (3550 RPM). At 50Hz it delivers up to 149 PSI at 400 GPM — sufficient for mid-rise standpipe systems. For sustained duties at the top of the pressure envelope, NMFIRE engineering confirms the impeller, casing, and driver selection against the certified performance curve and issues the project-specific factory test report for consultant approval.

What fire pump standards apply in African countries?

Most African countries have no domestic fire pump manufacturing standard; NFPA 20 is the reference standard most commonly adopted by fire consultants, insurers, and regulators across Kenya, Nigeria, Ghana, Tanzania, South Africa, and the wider region. UL Listing and FM Approval are the recognized third-party certifications for imported fire pumps. African grids are 50Hz, so the SCF100-80-250 2980 RPM (50Hz) configuration is the standard selection for these markets. NMFIRE supplies NFPA 20-compliant, UL/FM certified fire pumps and project documentation suited to consultant approval processes in these regions.

What applications suit a 400 GPM split case fire pump?

A 400 GPM fire pump is a typical duty for ordinary and light hazard occupancies requiring more capacity than the base 300 GPM rating: hotels and resorts (a frequent requirement in Kenya and across Africa), mid-rise commercial and residential buildings, hospitals, schools, and light manufacturing plants. With pressure capability up to 218 PSI, the SCF100-80-250 also covers standpipe systems in taller buildings. For higher flow duties (750 GPM and above), NMFIRE offers larger SCF series split case models.

What package options are available for the SCF100-80-250?

The SCF100-80-250 pump unit itself comprises the horizontal split case pump and its electric motor or diesel engine. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL/FM listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The SCF100-80-250 horizontal split case model is UL Listed and FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

Technical Guides & Resources
  • NFPA 20 Fire Pump Selection Guide — How to select the right pump for your project
  • 50Hz vs 60Hz Fire Pump Operation — Matching pump speed to your power grid
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • Split Case Fire Pump Design & Maintenance Guide — Casing access and in-place service
  • Diesel Engine Altitude & Temperature Derating — Sizing engines for site conditions
  • ODP vs TEFC Motor Selection — Matching motor enclosure to site environment
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • Fire Pump Package Components — Complete guide to pump, controller, jockey pump, relief valve
  • Skid-Mounted & Containerized Fire Pump Stations — Pre-assembled delivery options

NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.

Tags:

Similar Products