Home > products > > SCF125-80-200  UL/FM Horizontal Split Case Fire Pump  300–750 GPM, 500 GPM @ 75 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

SCF125-80-200  UL/FM Horizontal Split Case Fire Pump  300–750 GPM, 500 GPM @ 75 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: SCF125-80-200

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

UL/FM SCF125-80-200 Split Case Fire Pump

,

Horizontal Split Case Fire Pump

Discharge Size:
3-inch
Pressure Range:
91-132 PSI
Suction Size:
4-inch
Control Panel:
Automatic / Manual
Material:
Cast Iron / Stainless Steel
Mounting Type:
Horizontal
Pump Type:
Centrifugal
Speed:
1450-2950 RPM
Flow Rate:
500-2000 L/min
Power Source:
Electric / Diesel Engine
Phase:
3 Phase
Voltage:
380V / 415V / 440V
Application:
Fire Protection Systems
Discharge Size:
3-inch
Pressure Range:
91-132 PSI
Suction Size:
4-inch
Control Panel:
Automatic / Manual
Material:
Cast Iron / Stainless Steel
Mounting Type:
Horizontal
Pump Type:
Centrifugal
Speed:
1450-2950 RPM
Flow Rate:
500-2000 L/min
Power Source:
Electric / Diesel Engine
Phase:
3 Phase
Voltage:
380V / 415V / 440V
Application:
Fire Protection Systems
SCF125-80-200  UL/FM Horizontal Split Case Fire Pump  300–750 GPM, 500 GPM @ 75 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive
SCF125-80-200  UL/FM Horizontal Split Case Fire Pump  300–750 GPM, 500 GPM @ 75 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive
UL LISTED  |  FM APPROVED  |  NFPA 20 COMPLIANT  |  50Hz / 60Hz  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE SCF125-80-200 is a UL Listed and FM Approved horizontal split case fire pump covering 300–750 GPM with pressure from 50 to 103 PSI for NFPA 20 fire protection systems. At the 500 GPM duty point it delivers 50–77 PSI on 50Hz supply and up to 90 PSI on 60Hz supply, making it a versatile low-head 5-inch suction split case fire pump for warehouses, logistics centers, and commercial complexes across Africa and other export markets.

The pump is rated for dual-frequency operation: 2980 RPM at 50Hz — matching the power grids of Africa, the Middle East, Asia, and Europe — and 3550 RPM at 60Hz for the Americas. Driver options include ODP or TEFC electric motors (30–75 HP) and five NM4 series diesel engine models (39–86 HP) for sites with unreliable or no mains power, giving the widest diesel selection in the compact SCF range from a single pump model.

The horizontally split casing opens for service without disturbing the suction and discharge piping — impeller, wear rings, and gland packing can be inspected and replaced with the pump in place. The robust between-bearings shaft support delivers stable hydraulic performance across the whole 300–750 GPM range. Manufactured to NFPA 20 requirements with UL Listing and FM Approval, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

SCF125-80-200  UL/FM Horizontal Split Case Fire Pump  300–750 GPM, 500 GPM @ 75 PSI  50Hz (2980 RPM) / 60Hz (3550 RPM)  Electric or Diesel Drive

Key Specifications

Product Type: Horizontal Split Case Fire Pump
Model: SCF125-80-200
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 300-750 GPM
Pressure Range: 50-103 PSI (500 GPM duty: 50-90 PSI)
Pump Speed: 2980 RPM (50Hz) / 3550 RPM (60Hz)
Driver Type: ODP / TEFC Electric Motor (30-75 HP) or Diesel Engine (39-86 HP)
Pump Type: Horizontal Split Case
Application: Commercial / Industrial / Logistics / Infrastructure

Pump Range Overview
Parameter Specification
Rated Flow 300 / 400 / 450 / 500 / 750 GPM
Pressure Range 50 – 103 PSI
Head Range 38 – 70 m
Pump Speed 2980 RPM (50Hz) / 3550 RPM (60Hz)
Driver Options ODP / TEFC Motor 30 – 75 HP; Diesel Engine 39 – 86 HP
Certifications UL Listed / FM Approved
Suction / Discharge DN125 (5″) / DN80 (3″)
Example Duty Point Configuration
Parameter Value
Pump Model SCF125-80-200
Rated Flow 500 GPM
Rated Pressure 75 PSI
Pump Speed 2980 RPM (50Hz)
Max Shaft Power 40 HP / 30 kW
Motor Option F-TXC 324TS40U2B (40 HP TEFC)
Diesel Option NM4-90 (51 HP)
Controller Tornatech
Key Features
  • UL Listed and FM Approved dual certification
  • Designed and tested per NFPA 20 requirements
  • Dual-frequency operation — 2980 RPM (50Hz) and 3550 RPM (60Hz) from one pump model
  • 500 GPM duty point with pressure up to 103 PSI; 750 GPM extension at 60Hz for large-area sprinkler systems
  • Five diesel engine options (NM4 series, 39–86 HP) — the widest diesel selection in the compact SCF range
  • Electric motor drive (ODP / TEFC, 30–75 HP) or diesel engine drive (NM4 series, 39–86 HP)
  • Split case construction — internal parts serviceable without disturbing piping
  • Replaceable bronze wear rings maintain internal clearances and hydraulic efficiency
  • Diesel engine altitude and temperature derating calculated per site conditions
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
Applications

Warehouses & Logistics Centers

500 GPM at low head is a standard warehouse sprinkler duty — the SCF125-80-200 is a proven choice for logistics parks and distribution centers in Tanzania and across African markets on 50Hz power grids.

Commercial & Residential Complexes

Moderate pressure (50–103 PSI) covers ordinary-hazard sprinkler and hose demand for shopping complexes, apartment blocks, and office buildings without excess cost.

Light Manufacturing & Workshops

Reliable fire protection for factories and workshops with moderate capacity demand; the 750 GPM extension covers larger floor areas at 60Hz.

Sites Without Reliable Mains Power

Five NM4 diesel engine options keep the fire pump running through grid outages — the widest diesel selection in the compact SCF range, a frequent requirement for remote and rural project sites.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required motor power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Shaft AISI 4340
Shaft Sleeve SS304
Seal Gland Packing
Wear Ring Bronze
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

Dual-Frequency Operation & Driver Options
One Pump Model — Both Power Systems:
50Hz operation at 2980 RPM — matches power grids in Africa, the Middle East, Asia, and Europe; the standard configuration for Tanzanian, Nigerian, Ghanaian, and other African projects
60Hz operation at 3550 RPM — matches power grids in the Americas and other 60Hz territories; enables 750 GPM extension flow for larger systems
Same UL/FM certified hydraulics — the selection table covers both speeds, with driver size matched to each duty point
Electric Motor Options (ODP vs TEFC)

The SCF125-80-200 electric drive is available with motor size matched to each duty point from 30 to 75 HP:

  • ODP (Open Drip Proof) — economical enclosure for clean, dry, well-ventilated indoor pump rooms
  • TEFC (Totally Enclosed Fan Cooled) — sealed enclosure for dusty, humid, hot, or outdoor-adjacent environments; the common choice for African project sites
Diesel Engine Drive (NM4 Series — Five Options)

The SCF125-80-200 offers the widest diesel engine selection in the compact SCF range — five NM4 series models rated 39–86 HP at 2950 RPM (50Hz), giving maximum flexibility to match the exact duty point and site conditions:

  • NM4-90C — 39 HP, for low-pressure 50Hz duties
  • NM4-90 — 51 HP, the standard 50Hz diesel selection
  • NM4-90B — 61 HP, for mid-range pressure 50Hz duties
  • NM4-102C — 75 HP, for higher-pressure FM-rated 50Hz duties
  • NM4-105 — 86 HP, for the highest-pressure UL-rated 50Hz duties

Diesel packages include engine-driven cooling, starting batteries, and engine controller matched per NFPA 20. Note: diesel drive is available at 50Hz (2980 RPM) duty points only; 60Hz (3550 RPM) duty points are served by electric motor drive.

Altitude & Temperature Derating
Diesel Engine Derating per NFPA 20:
Engine nameplate power must be derated for site conditions:
• Approximately 3% power reduction per 300m (1000 ft) above sea level
• Approximately 1% power reduction per 5.5°C (10°F) above 25°C (77°F)

With five engine options spanning 39–86 HP, the SCF125-80-200 has particular flexibility to absorb altitude and temperature derating — if the standard engine derates below the required shaft power at site conditions, the next engine model up is available without changing the pump. NMFIRE engineering calculates derating factors based on actual project site conditions to ensure the engine has sufficient standby power at the specified flow and pressure duty point.
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a split case fire pump, and how does it work?

A horizontal split case fire pump has a casing split along the shaft centerline. Lifting the upper casing half exposes the impeller, wear rings, and shaft for inspection or parts replacement — without disconnecting the suction or discharge piping. The impeller is supported between two bearings, giving smooth, stable operation across a wide flow range. The NMFIRE SCF125-80-200 applies this design to the 300–750 GPM range with UL Listing and FM Approval per NFPA 20.

What is the difference between UL Listed and FM Approved fire pumps?

UL (Underwriters Laboratories) Listing and FM (FM Approvals) certification are two independent third-party certifications verifying that a fire pump meets the applicable standards (such as UL 448 and FM 1311). Both are widely accepted by fire protection consultants, insurers, and authorities having jurisdiction in export markets. Many projects specify either one; some require both. The SCF125-80-200 carries both UL Listing and FM Approval, giving maximum flexibility for consultant approval and insurance acceptance on international projects.

What is the flow and pressure range of the SCF125-80-200?

The SCF125-80-200 covers rated flows of 300, 400, 450, 500, and 750 GPM, with pressure ratings from 50 to 103 PSI (head 38–70 m). At the 500 GPM duty point, 50Hz operation (2980 RPM) delivers 50–77 PSI while 60Hz operation (3550 RPM) reaches up to 90 PSI. The 750 GPM extension is available at 60Hz only. Driver options span ODP/TEFC electric motors from 30 to 75 HP and five NM4 series diesel engines from 39 to 86 HP. The full selection table and performance curves for each flow/pressure/speed combination are available on request.

50Hz or 60Hz — which fire pump frequency do I need?

Match the pump to your site power supply. Most of Africa (including Tanzania, Nigeria, and Ghana), the Middle East, Asia, and Europe use 50Hz grids, where the SCF125-80-200 runs at 2980 RPM. The Americas and a few other territories use 60Hz, where the pump runs at 3550 RPM and can extend to 750 GPM. The same UL/FM certified pump model serves both — only the rated speed, pressure envelope, and driver selection differ. If your site has unreliable or no mains power, a diesel engine drive (rated at 2950 RPM, 50Hz duty points only) provides an independent backup per NFPA 20.

How do I size a split case fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off, pressure must not exceed 140% of rated. NMFIRE engineering can verify your duty point against the SCF125-80-200 selection table and issue a project-specific performance curve for consultant approval.

Split case vs end suction vs vertical inline fire pump — which should I choose?

Horizontal split case pumps are the most common fire pump type: easy to service in place, and suitable for medium to high flow duties (the SCF125-80-200 covers 300–750 GPM with pressure up to 103 PSI). End suction pumps offer a simple, economical layout for lower duties. Vertical inline pumps have the most compact footprint for space-limited plant rooms and retrofits. All three types are available from NMFIRE with UL Listed and FM Approved certification per NFPA 20. Selection depends on project flow, available space, and maintenance strategy.

Why does the SCF125-80-200 offer five diesel engine options?

The SCF125-80-200 has the widest diesel engine selection in the compact SCF range because its duty points span a broad pressure band (50–103 PSI) at five flow rates, each requiring a different shaft power. Rather than oversizing a single engine for all duties — which wastes fuel and cost — NMFIRE matches the engine to the exact duty point: NM4-90C (39 HP) for low-pressure duties, NM4-90 (51 HP) for standard duties, NM4-90B (61 HP) for mid-range, NM4-102C (75 HP) for higher-pressure FM-rated points, and NM4-105 (86 HP) for the highest-pressure UL-rated points. This also gives margin to absorb altitude and temperature derating — if the standard engine derates below the required power at site conditions, the next model up is available without changing the pump.

Can the SCF125-80-200 handle 750 GPM large-area sprinkler systems?

Yes. The SCF125-80-200 extends to 750 GPM at 60Hz (3550 RPM), with pressure from 66 to 103 PSI and shaft power up to 70 HP. This makes it suitable for large-area warehouse and logistics sprinkler systems that exceed the 500 GPM rating without needing a larger pump model. At 50Hz (2980 RPM), the maximum rated flow is 500 GPM. For projects requiring 750 GPM at 50Hz, NMFIRE offers larger SCF series models. The 750 GPM duty point is electric-drive only (no diesel option at 60Hz).

What applications suit a 500 GPM split case fire pump?

A 500 GPM fire pump at 50–90 PSI is a standard duty for ordinary-hazard occupancies: warehouses and logistics centers (a frequent requirement in Tanzania and across Africa), shopping complexes, apartment blocks, schools, and light manufacturing plants. The low-head characteristic of the SCF125-80-200 matches projects where the sprinkler demand is moderate rather than high-pressure standpipe. For higher flow duties, the 750 GPM extension at 60Hz covers larger floor areas from the same pump model.

What package options are available for the SCF125-80-200?

The SCF125-80-200 pump unit itself comprises the horizontal split case pump and its electric motor or diesel engine. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL/FM listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The SCF125-80-200 horizontal split case model is UL Listed and FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

Technical Guides & Resources
  • NFPA 20 Fire Pump Selection Guide — How to select the right pump for your project
  • 50Hz vs 60Hz Fire Pump Operation — Matching pump speed to your power grid
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • Five Diesel Engine Options — Matching NM4 engine model to duty point and site conditions
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • Split Case Fire Pump Design & Maintenance Guide — Casing access and in-place service
  • Diesel Engine Altitude & Temperature Derating — Sizing engines for site conditions
  • ODP vs TEFC Motor Selection — Matching motor enclosure to site environment
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • Low-Head Fire Pump Applications — Warehouse and logistics sprinkler system sizing