Product Details
Place of Origin: China
Brand Name: NMFIRE
Certification: NFPA20 UL FM
Model Number: ESF200/50G
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Plywood
Delivery Time: 80 days
Payment Terms: L/C,T/T
Supply Ability: 80 days
Phase: |
3 Phase |
Frequency: |
50Hz / 60Hz |
Mounting Type: |
Horizontal |
Type: |
Centrifugal Pump |
Standards Compliance: |
UL / FM / NFPA |
Phase: |
3 Phase |
Frequency: |
50Hz / 60Hz |
Mounting Type: |
Horizontal |
Type: |
Centrifugal Pump |
Standards Compliance: |
UL / FM / NFPA |
NMFIRE ESF200/50G is a UL Listed and FM Approved horizontal end suction fire pump delivering 2500 GPM at 99–174 PSI for NFPA 20 fire protection systems. As NMFIRE's flagship large end suction fire pump, this 2500 GPM duty serves oil and gas facilities, tank farms, power plants, and large industrial firewater systems across Nigeria and wider African markets.
The overhung-impeller, back pull-out construction keeps the footprint small and the installation straightforward — an economical alternative to horizontal split case pumps where the duty fits. The ESF200/50G is available with either an electric motor (ODP or TEFC enclosure, 200–400 HP) or a diesel engine driver (221–512 HP), so the same certified hydraulic package can be matched to reliable-grid sites or to weak-grid African locations where diesel drive is preferred for independence from the mains supply.
Manufactured to NFPA 20 requirements with ul listed and fm approved, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.
Product Type: Horizontal End Suction Fire Pump
Model: ESF200/50G
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Rated Flow: 2500 GPM
Pressure Range: 99-174 PSI
Driver Type: Electric Motor (ODP / TEFC) or Diesel Engine
Pump Speed: 1760 RPM (60 Hz)
Pump Type: Horizontal End Suction, Back Pull-Out
Application: Commercial / Industrial / Infrastructure
| Parameter | Specification |
|---|---|
| Rated Flow | 2500 GPM |
| Pressure Range | 99 – 174 PSI |
| Head Range | 70 – 122 m |
| Pump Speed | 1760 RPM (60 Hz) |
| Max Shaft Power | 456 HP / 340.0 kW |
| Driver | ODP / TEFC Electric Motor (200–400 HP) or Diesel Engine (221–512 HP) |
| Certifications | UL Listed / FM Approved |
| Parameter | Value |
|---|---|
| Pump Model | ESF200/50G |
| Rated Flow | 2500 GPM |
| Rated Pressure | 174 PSI |
| Max Shaft Power | 456 HP / 340.0 kW |
| Pump Speed | 1760 RPM |
| Motor Model | F-TXC586T400U4B (400 HP TEFC) |
| Controller | Tornatech |
Oil & Gas Facilities
Tank farms, process areas, terminals, and utility blocks requiring 2500 GPM firewater — a flagship duty across Nigeria and West Africa.
Power Plants & Heavy Industry
Turbine halls, boiler areas, and material handling systems with high-demand sprinkler and deluge networks.
Large Infrastructure Projects
Airports, metro depots, and industrial parks with centralized high-flow firewater mains.
Weak-Grid & Remote Sites
Diesel-driven configuration maintains full fire protection capability independent of the mains supply — suited to regions with unstable or unavailable grid power.
Need Technical Data & Pricing?
Get project-specific pump selection, performance curves, and quotation within 24 hours.
Contact: Tarik@nmfirepump.com
NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.
Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:
Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:
Critical components are processed through precision CNC machining. Quality control includes:
Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:
Our dedicated fire pump test bench enables:
| Component | Standard Material |
|---|---|
| Casing | Ductile Cast Iron |
| Impeller | SS304 |
| Shaft | SS420 |
| Seal | Gland Packing |
| Wear Ring | Brass |
| Bearing | SKF |
For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.
Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.
Standard Documents:
For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.
A horizontal end suction fire pump takes suction on the horizontal axis through the casing eye and discharges vertically from the top of the casing. Compared with a horizontal split case pump, the end suction layout is simpler, more compact, and more economical — well suited to large firewater duties. The NMFIRE ESF200/50G delivers 2500 GPM at 99–174 PSI in this format, UL Listed and FM Approved per NFPA 20, with a back pull-out design that allows the rotating assembly to be serviced without disturbing the piping.
Horizontal split case pumps split the casing horizontally, so internal parts are serviced by removing the top half without disturbing piping; they are typically used for medium to high flow duties. End suction pumps have a single-piece casing with suction on the axis and discharge on top — the most compact and economical layout for small to medium duties such as 50–750 GPM, and available from NMFIRE in high-flow ratings up to 2500 GPM. Vertical inline pumps mount the motor above the pump with both nozzles on the same vertical centerline, minimizing footprint in very tight plant rooms. All three types are available from NMFIRE with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.
The ESF200/50G is rated at 2500 GPM, with selectable pressure ratings from 99 to 174 PSI (head 70–122 m) at 1760 RPM (60 Hz). Maximum shaft power is 456 HP / 340.0 kW at the 174 PSI duty point. Each duty point is driven by a matched ODP or TEFC electric motor from 200 to 400 HP, or by a diesel engine (221 to 512 HP) where electric supply is unreliable. The full selection table and performance curves are available on request.
The choice depends on the reliability of the site power supply. Where the mains supply is dependable, an electric driven fire pump (ODP or TEFC enclosure) offers lower installed cost, simpler maintenance, and no fuel storage requirements. Where the grid is unstable or unavailable — common across many African project locations — a diesel driven fire pump keeps the fire protection system fully independent of mains power per NFPA 20. The ESF200/50G is certified with both driver options, so the same hydraulic package can be configured either way for your project.
Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure at the topmost outlet, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off (zero flow), pressure must not exceed 140% of rated. NMFIRE engineering can verify the duty point against the ESF200/50G selection table and issue a project-specific performance curve for consultant approval.
The ESF200/50G pump unit itself comprises the end suction pump and its electric motor or diesel engine driver. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL Listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.
A 2500 GPM fire pump is a flagship rating for the largest firewater duties: oil and gas tank farms, refineries, power plants, airports, and large industrial complexes. The ESF200/50G runs at 1760 RPM (60 Hz) for low-wear, long-life operation, and its electric or diesel drive options match both grid-reliable and weak-grid sites. As NMFIRE's flagship end suction model, it is backed by full engineering support and the widest configuration options, with the wider ESF series covering duties from 50 to 2500 GPM.
Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The ESF200/50G horizontal end suction model is UL Listed / FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.
Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.
NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.