Product Details
Place of Origin: China
Brand Name: NMFIRE
Certification: NFPA20 UL FM
Model Number: ESF150/40G
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Plywood
Delivery Time: 80 days
Payment Terms: L/C,T/T
Supply Ability: 80 days
Material: |
Cast Iron / Stainless Steel |
Phase: |
3 Phase |
Speed: |
1450-2950 RPM |
Frequency: |
50Hz / 60Hz |
Mounting Type: |
Horizontal |
Type: |
Centrifugal Pump |
Standards Compliance: |
UL / FM / NFPA |
Power Source: |
Electric / Diesel Engine |
Material: |
Cast Iron / Stainless Steel |
Phase: |
3 Phase |
Speed: |
1450-2950 RPM |
Frequency: |
50Hz / 60Hz |
Mounting Type: |
Horizontal |
Type: |
Centrifugal Pump |
Standards Compliance: |
UL / FM / NFPA |
Power Source: |
Electric / Diesel Engine |
NMFIRE ESF150/40G is a UL Listed and FM Approved diesel-driven horizontal end suction fire pump delivering 2000 GPM at 98–163 PSI for NFPA 20 fire protection systems. The 2000 GPM high-flow, diesel-driven configuration is engineered for mining and heavy industrial firewater systems where grid power is unstable or unavailable — a core duty across South African and wider African mining markets.
The overhung-impeller, back pull-out construction keeps the footprint compact and the installation straightforward — an economical alternative to horizontal split case pumps where the duty fits. The ESF150/40G is configured as a diesel-engine-driven fire pump (208–412 HP) — engineered for mines and heavy industrial sites where grid power is unstable or unavailable, and matched to dusty, high-ambient African operating conditions.
Manufactured to NFPA 20 requirements with ul listed and fm approved, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.
Product Type: Horizontal End Suction Fire Pump
Model: ESF150/40G
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Rated Flow: 2000 GPM
Pressure Range: 98-163 PSI
Driver Type: Diesel Engine
Pump Speed: 2100 RPM
Pump Type: Horizontal End Suction, Back Pull-Out
Application: Commercial / Industrial / Infrastructure
| Parameter | Specification |
|---|---|
| Rated Flow | 2000 GPM |
| Pressure Range | 98 – 163 PSI |
| Head Range | 69 – 115 m |
| Pump Speed | 2100 RPM |
| Max Shaft Power | 348 HP / 259.5 kW |
| Driver | Diesel Engine (208–412 HP) |
| Certifications | UL Listed / FM Approved |
| Parameter | Value |
|---|---|
| Pump Model | ESF150/40G |
| Rated Flow | 2000 GPM |
| Rated Pressure | 163 PSI |
| Max Shaft Power | 348 HP / 259.5 kW |
| Pump Speed | 2100 RPM |
| Driver Model | NM6-128B Diesel Engine (412 HP) |
| Controller | Tornatech |
South African Mining Operations
Firewater for processing plants, shaft headgear areas, workshops, and conveyor systems — engineered for the mining industry's demanding duty cycles.
Off-Grid & Weak-Grid Mine Sites
Diesel-driven package stays fully independent of unreliable or unavailable mains power, per NFPA 20 independence requirements.
Large Industrial Firewater Systems
2000 GPM high-flow duty for smelters, plants, and bulk storage terminals.
Remote & Harsh-Environment Sites
Diesel drive with robust cooling and filtration for dusty, high-ambient remote locations across Africa.
Need Technical Data & Pricing?
Get project-specific pump selection, performance curves, and quotation within 24 hours.
Contact: Tarik@nmfirepump.com
NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.
Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:
Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:
Critical components are processed through precision CNC machining. Quality control includes:
Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:
Our dedicated fire pump test bench enables:
| Component | Standard Material |
|---|---|
| Casing | Ductile Cast Iron |
| Impeller | SS304 |
| Shaft | SS420 |
| Seal | Gland Packing |
| Wear Ring | Brass |
| Bearing | SKF |
For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.
Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.
Standard Documents:
For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.
A horizontal end suction fire pump takes suction on the horizontal axis through the casing eye and discharges vertically from the top of the casing. Compared with a horizontal split case pump, the end suction layout is simpler, more compact, and more economical — well suited to large firewater duties. The NMFIRE ESF150/40G delivers 2000 GPM at 98–163 PSI in this format, UL Listed and FM Approved per NFPA 20, with a back pull-out design that allows the rotating assembly to be serviced without disturbing the piping.
Horizontal split case pumps split the casing horizontally, so internal parts are serviced by removing the top half without disturbing piping; they are typically used for medium to high flow duties. End suction pumps have a single-piece casing with suction on the axis and discharge on top — the most compact and economical layout for small to medium duties such as 50–750 GPM, and available from NMFIRE in high-flow ratings up to 2500 GPM. Vertical inline pumps mount the motor above the pump with both nozzles on the same vertical centerline, minimizing footprint in very tight plant rooms. All three types are available from NMFIRE with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.
The ESF150/40G is rated at 2000 GPM, with selectable pressure ratings from 98 to 163 PSI (head 69–115 m) at 2100 RPM. Maximum shaft power is 348 HP / 259.5 kW at the 163 PSI duty point. Each duty point is driven by a matched diesel engine (208–412 HP) selected for the site's ambient and altitude conditions. The full selection table and performance curves are available on request.
The ESF150/40G is configured exclusively as a diesel-driven fire pump. At 2000 GPM and up to 348 HP shaft power, this duty is typical of mining and heavy industrial sites — locations where grid power is often unstable or unavailable. A diesel engine driver (208–412 HP) keeps the firewater system fully independent of the mains supply per NFPA 20, which is why South African and wider African mining projects commonly specify diesel drive at this duty. For grid-reliable sites requiring electric drive at similar flows, NMFIRE offers the ESF150/32 (1500 GPM) and ESF200/50G (2500 GPM, electric or diesel).
Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure at the topmost outlet, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off (zero flow), pressure must not exceed 140% of rated. NMFIRE engineering can verify the duty point against the ESF150/40G selection table and issue a project-specific performance curve for consultant approval.
The ESF150/40G pump unit itself comprises the end suction pump and its diesel engine driver. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL Listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.
A 2000 GPM diesel-driven fire pump is a typical specification for mining operations — processing plants, shaft areas, conveyor corridors, workshops — and for heavy industrial sites such as smelters and bulk storage terminals, especially where grid power is unreliable. The ESF150/40G is engineered for exactly this profile: high flow, diesel independence, and robust construction for dusty, high-ambient remote environments. For grid-reliable sites, NMFIRE offers electric-driven end suction models at 1500 GPM (ESF150/32) and 2500 GPM (ESF200/50G).
Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The ESF150/40G horizontal end suction model is UL Listed / FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.
Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.
NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.
Tags: