Home > products > > SCF125-100-330x2  UL/FM Two-Stage Split Case Fire Pump  500–750 GPM, 500 GPM @ 330 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Diesel or Electric Drive — Up to 616 PSI

SCF125-100-330x2  UL/FM Two-Stage Split Case Fire Pump  500–750 GPM, 500 GPM @ 330 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Diesel or Electric Drive — Up to 616 PSI

Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: SCF125-100-330x2

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

58HP Split Case Fire Pump

,

616 PSI Split Case Fire Pump

,

Two-Stage Split Case Fire Pump

Discharge Size:
3-inch
Max Shaft Power:
58 HP
Pressure Range:
91-132 PSI
Head Range:
64-93 M
Suction Size:
4-inch
Flow Range:
300-500 GPM
Pump Speed:
3550 RPM
Motor Power:
40-60 HP
Control Panel:
Automatic / Manual
Pressure Rating:
10-16 Bar
Material:
Cast Iron / Stainless Steel
Mounting Type:
Horizontal
Motor Power:
15-100 KW
Pump Type:
Centrifugal
Speed:
1450-2950 RPM
Flow Rate:
500-2000 L/min
Power Source:
Electric / Diesel Engine
Discharge Size:
3-inch
Max Shaft Power:
58 HP
Pressure Range:
91-132 PSI
Head Range:
64-93 M
Suction Size:
4-inch
Flow Range:
300-500 GPM
Pump Speed:
3550 RPM
Motor Power:
40-60 HP
Control Panel:
Automatic / Manual
Pressure Rating:
10-16 Bar
Material:
Cast Iron / Stainless Steel
Mounting Type:
Horizontal
Motor Power:
15-100 KW
Pump Type:
Centrifugal
Speed:
1450-2950 RPM
Flow Rate:
500-2000 L/min
Power Source:
Electric / Diesel Engine
SCF125-100-330x2  UL/FM Two-Stage Split Case Fire Pump  500–750 GPM, 500 GPM @ 330 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Diesel or Electric Drive — Up to 616 PSI
SCF125-100-330x2  UL/FM Two-Stage Split Case Fire Pump  500–750 GPM, 500 GPM @ 330 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Diesel or Electric Drive — Up to 616 PSI
UL LISTED  |  FM APPROVED  |  NFPA 20 COMPLIANT  |  50Hz / 60Hz  |  Two-Stage High Pressure  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE SCF125-100-330x2 is a UL Listed and FM Approved two-stage horizontal split case fire pump delivering ultra-high pressure up to 616 PSI for NFPA 20 fire protection systems. At the 500 GPM duty point on 50Hz supply (2950 RPM) it delivers 284–405 PSI, while 60Hz operation (3550 RPM) extends to 616 PSI — making it the highest-pressure model in the NMFIRE SCF split case series for refineries, power plants, high-rise buildings, and heavy industrial fire protection across Africa and other export markets.

The "x2" in the model name denotes the two-stage impeller configuration: two impellers arranged in series within the split casing nearly double the pressure output of a single-stage pump at the same flow and speed. This makes the SCF125-100-330x2 the standard selection where system hydraulic calculations demand discharge pressures beyond the reach of conventional single-stage fire pumps.

The pump is rated for dual-frequency operation: 2950 RPM at 50Hz — matching the power grids of Africa, the Middle East, Asia, and Europe — and 3550 RPM at 60Hz for the Americas. A dedicated 2200 RPM diesel speed is available for 500 GPM duties at 162–212 PSI, giving longer engine life and quieter operation. Driver options include ODP or TEFC electric motors (200–400 HP) and three diesel engine models — NM4-104B, NM6-110D, and NM6-108E (109–335 HP) — making this the most diesel-capable pump in the SCF range for sites requiring NFPA 20 backup power on 50Hz grids.

The horizontally split casing opens for service without disturbing the suction and discharge piping — impeller, wear rings, and gland packing can be inspected and replaced with the pump in place. The robust between-bearings shaft support delivers stable hydraulic performance across the full 500–750 GPM range. Manufactured to NFPA 20 requirements with UL Listing and FM Approval, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

SCF125-100-330x2  UL/FM Two-Stage Split Case Fire Pump  500–750 GPM, 500 GPM @ 330 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Diesel or Electric Drive — Up to 616 PSI

Key Specifications

Product Type: Two-Stage Horizontal Split Case Fire Pump
Model: SCF125-100-330x2
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 500-750 GPM
Pressure Range: 162-616 PSI (500 GPM @ 50Hz: 284-405 PSI)
Pump Speed: 2200 RPM (diesel) / 2950 RPM (50Hz) / 3550 RPM (60Hz)
Driver Type: Diesel Engine (109-335 HP) or ODP / TEFC Electric Motor (200-400 HP)
Pump Type: Two-Stage Horizontal Split Case
Application: Refinery / Power Plant / High-Rise / Heavy Industrial

Pump Range Overview
Parameter Specification
Rated Flow 500 / 750 GPM
Pressure Range 162 – 616 PSI
Head Range 114 – 433 m
Pump Speed 2200 RPM (diesel) / 2950 RPM (50Hz) / 3550 RPM (60Hz)
Driver Options Diesel Engine 109 – 335 HP; ODP/TEFC Motor 200 – 400 HP
Certifications UL Listed / FM Approved
Suction / Discharge DN125 (5″) / DN100 (4″)
Example Duty Point Configuration
Parameter Value
Pump Model SCF125-100-330x2
Rated Flow 500 GPM
Rated Pressure 330 PSI
Pump Speed 2950 RPM (50Hz)
Max Shaft Power 185 HP / 138 kW
Motor Option F-TXC 447TS200U2B (200 HP TEFC)
Diesel Option NM6-110D / 2900 RPM (268 HP UL)
Controller Tornatech
Key Features
  • UL Listed and FM Approved dual certification
  • Two-stage impeller design — ultra-high pressure up to 616 PSI, far beyond single-stage pumps
  • Designed and tested per NFPA 20 requirements
  • 500–750 GPM flow coverage from one 5-inch suction pump model
  • Dual-frequency 50Hz / 60Hz operation — 2950 RPM matches African, Middle Eastern, Asian, and European grids
  • Three diesel engine options — NM4-104B (2200 RPM), NM6-110D, and NM6-108E (50Hz) for maximum NFPA 20 backup power flexibility
  • Dedicated 2200 RPM diesel-only speed for 500 GPM at 162–212 PSI — longer engine life, quieter operation (UL Listed)
  • Electric motor drive (ODP / TEFC, 200–400 HP) available at 50Hz and 60Hz
  • Split case construction — internal parts serviceable without disturbing piping
  • Diesel engine altitude and temperature derating calculated per site conditions
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
Applications

Refineries & Petrochemical Plants

Ultra-high pressure foam and water-spray systems for process areas — the two-stage design delivers the 300+ PSI discharge required by refinery fire water networks in Egypt and across African industrial markets on 50Hz grids.

Power Plants & Heavy Industry

Diesel-driven fire pump packages for sites where grid reliability cannot be guaranteed — the NM6 series diesel at 50Hz provides independent backup power per NFPA 20 for thermal and hydroelectric facilities.

High-Rise & Ultra-High-Rise Standpipe

With pressure capability up to 616 PSI, the two-stage design serves standpipe systems in ultra-high-rise towers and elevated storage tank applications that exceed single-stage pump limits.

Remote Sites & Off-Grid Installations

The 2200 RPM dedicated diesel speed keeps the fire pump running with no mains power at all — ideal for mining camps, pipeline stations, and remote infrastructure across Africa.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

Two-Stage Hydraulic Design

The SCF125-100-330x2 uses two impellers arranged in series within the split casing. The first-stage impeller pressurizes the fluid, which then passes through an inter-stage channel to the second-stage impeller for further pressure amplification. This configuration nearly doubles the discharge pressure compared to a single-stage pump at the same flow and speed, enabling the 616 PSI maximum rating that single-stage designs cannot achieve.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance across both stages:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required motor power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller (x2) SS304
Shaft AISI 4340
Shaft Sleeve SS304
Seal Gland Packing
Wear Ring Bronze
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

Speed & Driver Options
One Pump Model — Three Speed Selections:
50Hz operation at 2950 RPM — matches power grids in Africa, the Middle East, Asia, and Europe; the standard configuration for Egyptian, Ghanaian, Kenyan, Nigerian, and other African projects. Both electric and diesel drive available at this speed.
60Hz operation at 3550 RPM — matches power grids in the Americas and other 60Hz territories. Electric drive only (no diesel at 60Hz for this model).
2200 RPM diesel-only speed (UL Listed) — dedicated diesel engine speed for 500 GPM at 162–212 PSI, giving longer engine life and quieter operation. Not available at 750 GPM.
Same UL/FM certified two-stage hydraulics — the selection table covers all speeds, with driver size matched to each duty point
Diesel Engine Drive — Three Engine Models

The SCF125-100-330x2 offers the broadest diesel engine coverage in the SCF range, with three engine models matched to different speed and duty requirements:

  • NM4-104B (2200 RPM, 109 HP) — dedicated reduced-speed diesel for 500 GPM at 162–212 PSI (UL Listed). The 2200 RPM engine speed extends engine service life and reduces noise, ideal for occupied building pump rooms and remote installations.
  • NM6-110D (2900 RPM, 239–268 HP) — 50Hz diesel for both 500 and 750 GPM duty points at 284–405 PSI. The primary diesel selection for African projects on 50Hz grids requiring NFPA 20 backup power.
  • NM6-108E (2950 RPM, 335 HP) — 50Hz diesel for higher-pressure 500 and 750 GPM duty points at the top of the 50Hz pressure envelope (350–405 PSI).

Diesel packages include engine-driven cooling, starting batteries, and engine controller matched per NFPA 20. The diesel engine is the NFPA 20 preferred driver where a backup power source is required for the fire pump — common on African project sites with unreliable or no mains power.

Electric Motor Options (ODP vs TEFC)

The SCF125-100-330x2 electric drive is available with motor size matched to each duty point from 200 to 400 HP:

  • ODP (Open Drip Proof) — economical enclosure for clean, dry, well-ventilated indoor pump rooms
  • TEFC (Totally Enclosed Fan Cooled) — sealed enclosure for dusty, humid, hot, or outdoor-adjacent environments; the common choice for African project sites
50Hz Diesel — The Africa Standard:
On 50Hz grids (Africa, Middle East, Asia, Europe), the NM6-110D diesel engine at 2900 RPM provides independent backup fire pump drive with no dependency on mains power. This is the most common diesel configuration for Egyptian, Ghanaian, Kenyan, and Nigerian fire protection projects requiring NFPA 20 compliance with a reliable backup driver.
Altitude & Temperature Derating
Diesel Engine Derating per NFPA 20:
Engine nameplate power must be derated for site conditions:
• Approximately 3% power reduction per 300m (1000 ft) above sea level
• Approximately 1% power reduction per 5.5°C (10°F) above 25°C (77°F)

NMFIRE engineering calculates derating factors based on actual project site conditions to ensure the engine has sufficient standby power at the specified flow and pressure duty point. This is especially critical for the SCF125-100-330x2, where the high-pressure two-stage duty demands substantial engine power — derating verification is mandatory before final engine selection.
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


SCF125-100-330x2  UL/FM Two-Stage Split Case Fire Pump  500–750 GPM, 500 GPM @ 330 PSI  50Hz (2950 RPM) / 60Hz (3550 RPM)  Diesel or Electric Drive — Up to 616 PSI

FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a two-stage split case fire pump, and why choose one?

A two-stage split case fire pump uses two impellers arranged in series within the split casing. The first stage pressurizes the fluid, and the second stage further amplifies the pressure — nearly doubling the discharge pressure of a single-stage pump at the same flow and speed. The SCF125-100-330x2 reaches up to 616 PSI, far beyond the 279 PSI maximum of single-stage SCF models. Choose a two-stage pump when system hydraulic calculations demand discharge pressures that exceed single-stage capabilities — typical for refineries, ultra-high-rise standpipe systems, and heavy industrial fire water networks.

What is the difference between UL Listed and FM Approved fire pumps?

UL (Underwriters Laboratories) Listing and FM (FM Approvals) certification are two independent third-party certifications verifying that a fire pump meets the applicable standards (such as UL 448 and FM 1311). Both are widely accepted by fire protection consultants, insurers, and authorities having jurisdiction in export markets. Many projects specify either one; some require both. The SCF125-100-330x2 carries both UL Listing and FM Approval, giving maximum flexibility for consultant approval and insurance acceptance on international projects.

What is the flow and pressure range of the SCF125-100-330x2?

The SCF125-100-330x2 covers rated flows of 500 and 750 GPM, with pressure ratings from 162 to 616 PSI (head 114–433 m). At the 500 GPM duty point, 50Hz operation (2950 RPM) delivers 284–405 PSI while 60Hz operation (3550 RPM) reaches up to 616 PSI. The 2200 RPM diesel-only speed covers 162–212 PSI at 500 GPM (UL Listed). Driver options span diesel engines from 109 to 335 HP (three engine models) and ODP/TEFC electric motors from 200 to 400 HP. The full selection table and performance curves for each flow/pressure/speed combination are available on request.

50Hz or 60Hz — which fire pump frequency do I need?

Match the pump to your site power supply. Most of Africa (including Egypt, Ghana, Kenya, and Nigeria), the Middle East, Asia, and Europe use 50Hz grids, where the SCF125-100-330x2 runs at 2950 RPM. The Americas and a few other territories use 60Hz, where the pump runs at 3550 RPM. The same UL/FM certified pump model serves both — only the rated speed, pressure envelope, and driver selection differ. If your site has unreliable or no mains power, a diesel engine drive at 50Hz (NM6-110D or NM6-108E at 2900–2950 RPM) or the dedicated 2200 RPM diesel speed provides an independent backup per NFPA 20.

Why does the SCF125-100-330x2 have three diesel engine options?

The SCF125-100-330x2 is the most diesel-capable pump in the NMFIRE SCF range, with three engine models covering different speed and duty requirements:

NM4-104B (2200 RPM, 109 HP) — a dedicated reduced-speed diesel for 500 GPM at 162–212 PSI (UL Listed only). Lower engine speed means longer service life, lower maintenance, and quieter operation — preferred for occupied building pump rooms and noise-sensitive sites.
NM6-110D (2900 RPM, 239–268 HP) — the primary 50Hz diesel for both 500 and 750 GPM at 284–405 PSI. The standard selection for African projects requiring NFPA 20 backup power on 50Hz grids.
NM6-108E (2950 RPM, 335 HP) — for higher-pressure 50Hz duties at the top of the pressure envelope (350–405 PSI).

The three-engine approach lets NMFIRE match the engine to the exact duty point and site conditions rather than oversizing a single engine across all duties.

How do I size a split case fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off, pressure must not exceed 140% of rated. For high-pressure duties exceeding 279 PSI, the two-stage SCF125-100-330x2 is the appropriate selection. NMFIRE engineering can verify your duty point against the selection table and issue a project-specific performance curve for consultant approval.

Split case vs end suction vs vertical inline fire pump — which should I choose?

Horizontal split case pumps are the most common fire pump type: easy to service in place, and suitable for medium to high flow duties (the SCF125-100-330x2 covers 500–750 GPM with pressure up to 616 PSI in two-stage configuration). End suction pumps offer a simple, economical layout for lower duties. Vertical inline pumps have the most compact footprint for space-limited plant rooms and retrofits. All three types are available from NMFIRE with UL Listed and FM Approved certification per NFPA 20. Selection depends on project flow, pressure, available space, and maintenance strategy.

Can the SCF125-100-330x2 be supplied with diesel or electric drive?

Yes. The same UL/FM certified pump is available with NM4/NM6 series diesel engine drive (109–335 HP across three engine models at 2200 or 2900–2950 RPM) or with ODP/TEFC electric motor drive (200–400 HP, 50Hz or 60Hz). Diesel drive is the NFPA 20 preferred choice where a backup power source is required — common on sites with unreliable grids across Africa. The 2200 RPM dedicated diesel speed is available for 500 GPM at 162–212 PSI (UL Listed). Note that diesel drive is available at 50Hz only for this model; 60Hz operation is electric-only. Engine power is verified per site altitude and ambient temperature per NFPA 20 derating rules.

Can the SCF125-100-330x2 handle ultra-high pressure up to 616 PSI?

Yes. The SCF125-100-330x2 is the highest-pressure model in the NMFIRE SCF split case range, reaching 616 PSI at 60Hz (3550 RPM) thanks to its two-stage impeller design. At the 500 GPM duty point it delivers up to 405 PSI on 50Hz and up to 616 PSI on 60Hz — sufficient for refinery fire water networks, ultra-high-rise standpipe systems, and elevated storage tank applications. For sustained duties at the top of the pressure envelope, NMFIRE engineering confirms the impeller, casing, and driver selection against the certified performance curve and issues the project-specific factory test report for consultant approval.

What fire pump standards apply in African countries?

Most African countries have no domestic fire pump manufacturing standard; NFPA 20 is the reference standard most commonly adopted by fire consultants, insurers, and regulators across Egypt, Ghana, Kenya, Nigeria, Tanzania, South Africa, and the wider region. UL Listing and FM Approval are the recognized third-party certifications for imported fire pumps. African grids are 50Hz, so the SCF125-100-330x2 2950 RPM (50Hz) configuration — with NM6-110D diesel backup — is the standard selection for these markets. NMFIRE supplies NFPA 20-compliant, UL/FM certified fire pumps and project documentation suited to consultant approval processes in these regions.

What applications suit a 500 GPM ultra-high-pressure two-stage fire pump?

A 500 GPM two-stage fire pump with pressure up to 616 PSI is suited to the most demanding fire protection duties: refinery and petrochemical process areas (a frequent requirement in Egypt and across African industrial markets), thermal and hydroelectric power plants, ultra-high-rise standpipe systems, elevated storage tank fill, and heavy industrial fire water networks. The 2200 RPM diesel option extends coverage to remote sites and off-grid installations at 162–212 PSI. For higher flow duties, the same pump model extends to 750 GPM.

What package options are available for the SCF125-100-330x2?

The SCF125-100-330x2 pump unit itself comprises the two-stage horizontal split case pump and its diesel engine or electric motor. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL/FM listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The SCF125-100-330x2 two-stage horizontal split case model is UL Listed and FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

Technical Guides & Resources
  • Two-Stage Fire Pump Design — When to choose two-stage over single-stage
  • 50Hz vs 60Hz Fire Pump Operation — Matching pump speed to your power grid
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • Reduced-Speed 2200 RPM Diesel Fire Pump Selections — Engine life and noise benefits
  • 50Hz Diesel Engine Backup — NM6 series for African 50Hz grids
  • Ultra-High-Pressure Standpipe Systems — Sizing fire pumps up to 616 PSI
  • Refinery Fire Water Networks — Two-stage pump selection for process area protection
  • Diesel Engine Altitude & Temperature Derating — Sizing engines for site conditions
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • Split Case Fire Pump Design & Maintenance Guide — Casing access and in-place service
  • ODP vs TEFC Motor Selection — Matching motor enclosure to site environment
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • Fire Pump Package Components — Complete guide to pump, controller, jockey pump, relief valve
  • Skid-Mounted & Containerized Fire Pump Stations — Pre-assembled delivery options

NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.