Place of Origin: China
Brand Name: NMFIRE
Certification: NFPA20 UL FM
Model Number: ESF40/20
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Plywood
Delivery Time: 80 days
Payment Terms: L/C,T/T
Supply Ability: 80 days
Mounting Type: |
Horizontal |
Material: |
Cast Iron / Stainless Steel |
Power Source: |
Electric Motor / Diesel Engine |
Phase: |
3 Phase |
Speed: |
1450-2950 RPM |
Inlet Size: |
50-200 Mm |
Frequency: |
50Hz / 60Hz |
Pump Type: |
Centrifugal Pump |
Mounting Type: |
Horizontal |
Material: |
Cast Iron / Stainless Steel |
Power Source: |
Electric Motor / Diesel Engine |
Phase: |
3 Phase |
Speed: |
1450-2950 RPM |
Inlet Size: |
50-200 Mm |
Frequency: |
50Hz / 60Hz |
Pump Type: |
Centrifugal Pump |
NMFIRE ESF40/20 is a UL Listed and FM Approved horizontal end suction fire pump delivering 50 GPM at 76–157 PSI for NFPA 20 fire protection systems. This 50 GPM duty is a compact rating for small commercial buildings, retail units, and light industrial facilities across Nigeria and wider African markets.
The overhung-impeller, back pull-out construction keeps the footprint small and the installation straightforward — an economical alternative to horizontal split case pumps where the duty fits. The ESF40/20 is available with either an electric motor (ODP or TEFC enclosure, 15–30 HP) or a diesel engine driver (39–61 HP), so the same certified hydraulic package can be matched to reliable-grid sites or to weak-grid African locations where diesel drive is preferred for independence from the mains supply.
Manufactured to NFPA 20 requirements with ul listed and fm approved, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.
Product Type: Horizontal End Suction Fire Pump
Model: ESF40/20
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Rated Flow: 50 GPM
Pressure Range: 76-157 PSI
Driver Type: Electric Motor (ODP / TEFC) or Diesel Engine
Pump Speed: 2980 RPM (50 Hz) / 3550 RPM (60 Hz)
Pump Type: Horizontal End Suction, Back Pull-Out
Application: Commercial / Industrial / Infrastructure
| Parameter | Specification |
|---|---|
| Rated Flow | 50 GPM |
| Pressure Range | 76 – 157 PSI |
| Head Range | 51 – 110 m |
| Pump Speed | 2980 RPM (50 Hz) / 3550 RPM (60 Hz) |
| Max Shaft Power | 31 HP / 23.1 kW |
| Driver | ODP / TEFC Electric Motor (15–30 HP) or Diesel Engine (39–61 HP) |
| Certifications | UL Listed / FM Approved |
| Parameter | Value |
|---|---|
| Pump Model | ESF40/20 |
| Rated Flow | 50 GPM |
| Rated Pressure | 111 PSI |
| Max Shaft Power | 20 HP / 14.9 kW |
| Pump Speed | 2980 RPM (50 Hz) |
| Motor Model | F-TXC 256T20U2B (20 HP TEFC) |
| Controller | Tornatech |
Small Commercial Buildings
Offices, shops, restaurants, and small apartment blocks needing a compact 50 GPM fire pump — a common duty across Nigeria's commercial building market.
Hotels & Guesthouses
Light hazard sprinkler and standpipe systems with limited plant room space.
Small Industrial & Workshops
Compact, cost-effective fire pump packages for light hazard industrial units and workshops.
Weak-Grid & Remote Sites
Diesel-driven configuration maintains full fire protection capability independent of the mains supply — suited to regions with unstable or unavailable grid power.
Need Technical Data & Pricing?
Get project-specific pump selection, performance curves, and quotation within 24 hours.
Contact: Tarik@nmfirepump.com
NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.
Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:
Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:
Critical components are processed through precision CNC machining. Quality control includes:
Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:
Our dedicated fire pump test bench enables:
| Component | Standard Material |
|---|---|
| Casing | Ductile Cast Iron |
| Impeller | SS304 |
| Shaft | SS420 |
| Seal | Gland Packing |
| Wear Ring | Brass |
| Bearing | SKF |
For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.
Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.
Standard Documents:
For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.
A horizontal end suction fire pump takes suction on the horizontal axis through the casing eye and discharges vertically from the top of the casing. Compared with a horizontal split case pump, the end suction layout is simpler, more compact, and more economical — well suited to smaller fire protection duties. The NMFIRE ESF40/20 delivers 50 GPM at 76–157 PSI in this format, UL Listed and FM Approved per NFPA 20, with a back pull-out design that allows the rotating assembly to be serviced without disturbing the piping.
Horizontal split case pumps split the casing horizontally, so internal parts are serviced by removing the top half without disturbing piping; they are typically used for medium to high flow duties. End suction pumps have a single-piece casing with suction on the axis and discharge on top — the most compact and economical layout for small to medium duties such as 50–750 GPM, and available from NMFIRE in high-flow ratings up to 2500 GPM. Vertical inline pumps mount the motor above the pump with both nozzles on the same vertical centerline, minimizing footprint in very tight plant rooms. All three types are available from NMFIRE with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.
The ESF40/20 is rated at 50 GPM, with selectable pressure ratings from 76 to 157 PSI (head 51–110 m) at 2980 RPM (50 Hz) / 3550 RPM (60 Hz). Maximum shaft power is 20 HP / 14.9 kW at the 111 PSI duty point. Each duty point is driven by a matched ODP or TEFC electric motor from 15 to 30 HP, or by a diesel engine (39 to 61 HP) where electric supply is unreliable. The full selection table and performance curves are available on request.
The choice depends on the reliability of the site power supply. Where the mains supply is dependable, an electric driven fire pump (ODP or TEFC enclosure) offers lower installed cost, simpler maintenance, and no fuel storage requirements. Where the grid is unstable or unavailable — common across many African project locations — a diesel driven fire pump keeps the fire protection system fully independent of mains power per NFPA 20. The ESF40/20 is certified with both driver options, so the same hydraulic package can be configured either way for your project.
Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure at the topmost outlet, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off (zero flow), pressure must not exceed 140% of rated. NMFIRE engineering can verify the duty point against the ESF40/20 selection table and issue a project-specific performance curve for consultant approval.
The ESF40/20 pump unit itself comprises the end suction pump and its electric motor or diesel engine driver. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL Listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.
A 50 GPM fire pump is a compact rating for light hazard occupancies: small offices, shops, restaurants, guesthouses, and small apartment blocks. The ESF40/20's 76–157 PSI range (50 Hz and 60 Hz options) covers most small-system pressure demands, and its diesel-driven option suits remote or weak-grid sites such as rural guesthouses and off-grid facilities. For larger duties (100–2500 GPM), NMFIRE offers a full range of end suction, horizontal split case, and vertical inline models.
Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The ESF40/20 horizontal end suction model is UL Listed / FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.
Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.
NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.
Tags: