logo
Wuhan Spico Machinery & Electronics Co., Ltd.
products
products
Home > products > > ESF150/32 UL/FM Horizontal End Suction Fire Pump 1500 GPM @ 119–187 PSI Designed For NFPA 20 Fire Protection Systems

ESF150/32 UL/FM Horizontal End Suction Fire Pump 1500 GPM @ 119–187 PSI Designed For NFPA 20 Fire Protection Systems

Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: ESF150/32

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

ESF150/32 End Suction Fire Pump 

,

NFPA 20 End Suction Fire Pump 

Material:
Cast Iron/Stainless Steel
Productname:
Fire Sprinkler Pump
Speed:
1450-2950 RPM
Phase:
3 Phase
Powersource:
Electric/Diesel
Installationtype:
Horizontal/Vertical
Material:
Cast Iron/Stainless Steel
Productname:
Fire Sprinkler Pump
Speed:
1450-2950 RPM
Phase:
3 Phase
Powersource:
Electric/Diesel
Installationtype:
Horizontal/Vertical
ESF150/32 UL/FM Horizontal End Suction Fire Pump 1500 GPM @ 119–187 PSI Designed For NFPA 20 Fire Protection Systems
ESF150/32 UL/FM Horizontal End Suction Fire Pump 1500 GPM @ 119–187 PSI Designed For NFPA 20 Fire Protection Systems
UL LISTED  |  FM APPROVED  |  NFPA 20 COMPLIANT  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE ESF150/32 is a UL Listed and FM Approved horizontal end suction fire pump delivering 1500 GPM at 119–187 PSI for NFPA 20 fire protection systems. This 1500 GPM high-flow duty serves refinery and petrochemical firewater systems, large industrial complexes, and high-hazard storage across Egypt and wider African markets.

The overhung-impeller, back pull-out construction keeps the footprint small and the installation straightforward — an economical alternative to horizontal split case pumps where the duty fits. The ESF150/32 is available with either an electric motor (ODP or TEFC enclosure, 150–250 HP) or a diesel engine driver (192–335 HP), so the same certified hydraulic package can be matched to reliable-grid sites or to weak-grid African locations where diesel drive is preferred for independence from the mains supply.

Manufactured to NFPA 20 requirements with ul listed and fm approved, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

Key Specifications

Product Type: Horizontal End Suction Fire Pump
Model: ESF150/32
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Rated Flow: 1500 GPM
Pressure Range: 119-187 PSI
Driver Type: Electric Motor (ODP / TEFC) or Diesel Engine
Pump Speed: 2980 RPM (50 Hz)
Pump Type: Horizontal End Suction, Back Pull-Out
Application: Commercial / Industrial / Infrastructure

Pump Range Overview
Parameter Specification
Rated Flow 1500 GPM
Pressure Range 119 – 187 PSI
Head Range 84 – 132 m
Pump Speed 2980 RPM (50 Hz)
Max Shaft Power 280 HP / 208.8 kW
Driver ODP / TEFC Electric Motor (150–250 HP) or Diesel Engine (192–335 HP)
Certifications UL Listed / FM Approved
Example Duty Point Configuration
Parameter Value
Pump Model ESF150/32
Rated Flow 1500 GPM
Rated Pressure 187 PSI
Max Shaft Power 280 HP / 208.8 kW
Pump Speed 2980 RPM
Motor Model F-TXC 449TS250U2B (250 HP TEFC)
Controller Tornatech
Key Features
  • UL Listed and FM Approved dual certification
  • Designed and tested per NFPA 20 requirements
  • 1500 GPM duty point with selectable pressure ratings from 119 to 187 PSI
  • Choice of electric motor drive (ODP / TEFC, 150–250 HP) or diesel engine drive — matched to site power conditions
  • High-flow duty for large industrial and mining firewater systems
  • Compact end suction layout — economical footprint versus split case equivalents
  • Back pull-out construction — rotating assembly serviced without disturbing suction and discharge piping
  • SS420 stainless steel shaft with SKF bearings — corrosion-resistant, reliable, globally sourced spares
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
Applications

Refineries & Petrochemical Plants

1500 GPM high-flow firewater for process units, tank farms, and loading areas — a core duty for refinery projects across Egypt and North Africa.

Large Industrial Complexes

Fertilizer, cement, steel, and heavy manufacturing facilities with high-demand firewater networks.

High-Hazard Storage & Logistics

Warehouses and distribution centers with high-hazard commodity classifications per NFPA 20.

Weak-Grid & Remote Sites

Diesel-driven configuration maintains full fire protection capability independent of the mains supply — suited to regions with unstable or unavailable grid power.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required engine power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Shaft SS420
Seal Gland Packing
Wear Ring Brass
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

ESF Design & Maintenance Features
Horizontal End Suction Fire Pump — Design Advantages:
Compact footprint — overhung-impeller end suction layout needs less floor space than an equivalent split case pump, fitting small plant rooms and budget-conscious projects
Back pull-out construction — the rotating assembly (impeller, shaft, gland packing, wear ring) is removed from the back of the pump without disturbing the suction and discharge piping, minimizing maintenance downtime
SS420 stainless steel shaft — high strength with good corrosion resistance at the sealing area
Gland packing seal — robust and field-serviceable, standard for fire pump duty
SKF bearings — internationally sourced, spares available worldwide
Brass wear ring — replaceable running clearance protects the casing and impeller
Dual driver options — ODP or TEFC electric motor (150–250 HP) for reliable-grid sites, or diesel engine (192–335 HP) for weak-grid and remote locations
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a horizontal end suction fire pump, and why choose the ESF150/32?

A horizontal end suction fire pump takes suction on the horizontal axis through the casing eye and discharges vertically from the top of the casing. Compared with a horizontal split case pump, the end suction layout is simpler, more compact, and more economical — well suited to large firewater duties. The NMFIRE ESF150/32 delivers 1500 GPM at 119–187 PSI in this format, UL Listed and FM Approved per NFPA 20, with a back pull-out design that allows the rotating assembly to be serviced without disturbing the piping.

What is the difference between end suction, horizontal split case, and vertical inline fire pumps?

Horizontal split case pumps split the casing horizontally, so internal parts are serviced by removing the top half without disturbing piping; they are typically used for medium to high flow duties. End suction pumps have a single-piece casing with suction on the axis and discharge on top — the most compact and economical layout for small to medium duties such as 50–750 GPM, and available from NMFIRE in high-flow ratings up to 2500 GPM. Vertical inline pumps mount the motor above the pump with both nozzles on the same vertical centerline, minimizing footprint in very tight plant rooms. All three types are available from NMFIRE with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.

What is the flow and pressure range of the ESF150/32?

The ESF150/32 is rated at 1500 GPM, with selectable pressure ratings from 119 to 187 PSI (head 84–132 m) at 2980 RPM (50 Hz). Maximum shaft power is 280 HP / 208.8 kW at the 187 PSI duty point. Each duty point is driven by a matched ODP or TEFC electric motor from 150 to 250 HP, or by a diesel engine (192 to 335 HP) where electric supply is unreliable. The full selection table and performance curves are available on request.

Should I choose an electric or diesel driven end suction fire pump?

The choice depends on the reliability of the site power supply. Where the mains supply is dependable, an electric driven fire pump (ODP or TEFC enclosure) offers lower installed cost, simpler maintenance, and no fuel storage requirements. Where the grid is unstable or unavailable — common across many African project locations — a diesel driven fire pump keeps the fire protection system fully independent of mains power per NFPA 20. The ESF150/32 is certified with both driver options, so the same hydraulic package can be configured either way for your project.

How do I size a fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure at the topmost outlet, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off (zero flow), pressure must not exceed 140% of rated. NMFIRE engineering can verify the duty point against the ESF150/32 selection table and issue a project-specific performance curve for consultant approval.

What package options are available for the ESF150/32?

The ESF150/32 pump unit itself comprises the end suction pump and its electric motor or diesel engine driver. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL Listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

What applications suit a 1500 GPM end suction fire pump?

A 1500 GPM fire pump is a typical rating for refinery and petrochemical firewater systems, tank farms, fertilizer and cement plants, and large high-hazard warehouses. The ESF150/32 delivers 119–187 PSI, covering the residual pressure demands of most industrial firewater networks, and its diesel-driven option suits Egyptian and wider African sites with weak grid supply. NMFIRE also offers 50–2500 GPM end suction models plus split case and vertical inline alternatives.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The ESF150/32 horizontal end suction model is UL Listed / FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

Technical Guides & Resources
  • NFPA 20 Fire Pump Selection Guide — How to select the right pump for your project
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • End Suction vs Split Case Fire Pump — Choosing the right configuration for your duty
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • Fire Pump Package Components — Complete guide to pump, controller, jockey pump, relief valve
  • Skid-Mounted & Containerized Fire Pump Stations — Pre-assembled delivery options

NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.

Tags:

Similar Products