Product Details
Place of Origin: China
Brand Name: NMFIRE
Certification: NFPA20 UL FM
Model Number: SCF125-100-300
Payment & Shipping Terms
Minimum Order Quantity: 1
Packaging Details: Plywood
Delivery Time: 80 days
Payment Terms: L/C,T/T
Supply Ability: 80 days
Discharge Size: |
3-inch |
Pressure Range: |
91-132 PSI |
Head Range: |
64-93 M |
Suction Size: |
4-inch |
Flow Range: |
300-500 GPM |
Pump Speed: |
3550 RPM |
Discharge Size: |
3-inch |
Pressure Range: |
91-132 PSI |
Head Range: |
64-93 M |
Suction Size: |
4-inch |
Flow Range: |
300-500 GPM |
Pump Speed: |
3550 RPM |
NMFIRE SCF125-100-300 is a UL Listed and FM Approved horizontal split case fire pump covering 300–750 GPM with pressure up to 279 PSI for NFPA 20 fire protection systems. At the 450 GPM duty point it delivers 147–203 PSI on 50Hz supply and up to 272 PSI on 60Hz supply, making it a high-capacity, high-pressure 5-inch suction split case fire pump for shopping malls, hospitals, industrial plants, and high-rise buildings across Africa and other export markets.
The pump is rated for dual-frequency operation: 2980 RPM at 50Hz — matching the power grids of Africa, the Middle East, Asia, and Europe — and 3550 RPM at 60Hz for the Americas. A further 2200 RPM diesel selection covers lower-pressure duties with reduced engine speed for longer engine life and quieter operation. Driver options include ODP or TEFC electric motors (100–200 HP) and NM4/NM6 series diesel engines (94–192 HP) for sites with unreliable or no mains power, so a single pump model serves both electric and diesel fire pump configurations.
The horizontally split casing opens for service without disturbing the suction and discharge piping — impeller, wear rings, and gland packing can be inspected and replaced with the pump in place. The robust between-bearings shaft support delivers stable hydraulic performance across the whole 300–750 GPM range. Manufactured to NFPA 20 requirements with UL Listing and FM Approval, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.
![]()
Product Type: Horizontal Split Case Fire Pump
Model: SCF125-100-300
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 300-750 GPM
Pressure Range: 78-279 PSI (450 GPM duty: 147-203 PSI @ 50Hz)
Pump Speed: 2200 RPM (diesel) / 2980 RPM (50Hz) / 3550 RPM (60Hz)
Driver Type: ODP / TEFC Electric Motor (100-200 HP) or Diesel Engine (94-192 HP)
Pump Type: Horizontal Split Case
Application: Commercial / Industrial / Infrastructure
| Parameter | Specification |
|---|---|
| Rated Flow | 300 / 400 / 450 / 500 / 750 GPM |
| Pressure Range | 78 – 279 PSI |
| Head Range | 84 – 148 m |
| Pump Speed | 2200 RPM (diesel) / 2980 RPM (50Hz) / 3550 RPM (60Hz) |
| Driver Options | ODP / TEFC Motor 100 – 200 HP; Diesel Engine 94 – 192 HP |
| Certifications | UL Listed / FM Approved |
| Suction / Discharge | DN125 (5″) / DN100 (4″) |
| Parameter | Value |
|---|---|
| Pump Model | SCF125-100-300 |
| Rated Flow | 450 GPM |
| Rated Pressure | 195 PSI |
| Pump Speed | 2980 RPM (50Hz) |
| Max Shaft Power | 113 HP / 84 kW |
| Motor Option | F-TXC 444TS125U2B (125 HP TEFC) |
| Diesel Option | NM4-108B (121 HP) |
| Controller | Tornatech |
Shopping Malls & Commercial Complexes
Dependable 450 GPM sprinkler and standpipe water supply for large retail and mixed-use developments — a core fire protection duty in Ghana and wider African markets on 50Hz power grids.
Hospitals & Institutional Buildings
Stable hydraulic performance and in-place serviceability for hospitals, universities, and government facilities where system uptime is critical.
High-Rise & Standpipe Systems
Pressure capability up to 279 PSI covers standpipe systems in mid- and high-rise offices, residential towers, and hotels.
Industrial Plants & Sites Without Reliable Mains Power
NM4/NM6 series diesel engine drive keeps the fire pump running through grid outages — a frequent requirement for factories and remote project sites.
Need Technical Data & Pricing?
Get project-specific pump selection, performance curves, and quotation within 24 hours.
Contact: Tarik@nmfirepump.com
![]()
NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.
Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:
Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:
Critical components are processed through precision CNC machining. Quality control includes:
Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:
Our dedicated fire pump test bench enables:
| Component | Standard Material |
|---|---|
| Casing | Ductile Cast Iron |
| Impeller | SS304 |
| Shaft | AISI 4340 |
| Shaft Sleeve | SS304 |
| Seal | Gland Packing |
| Wear Ring | Bronze |
| Bearing | SKF |
For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.
The SCF125-100-300 electric drive is available with motor size matched to each duty point from 100 to 200 HP:
For sites with unreliable mains power or no grid connection, the SCF125-100-300 can be driven by an NM4 or NM6 series diesel engine rated 94–192 HP at 2950 RPM — the NFPA 20 preferred configuration where a backup power source is required for the fire pump. Reduced-speed 2200 RPM diesel selections are also available for lower-pressure duties. Diesel packages include engine-driven cooling, starting batteries, and engine controller matched per NFPA 20.
Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.
Standard Documents:
For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.
![]()
A horizontal split case fire pump has a casing split along the shaft centerline. Lifting the upper casing half exposes the impeller, wear rings, and shaft for inspection or parts replacement — without disconnecting the suction or discharge piping. The impeller is supported between two bearings, giving smooth, stable operation across a wide flow range. The NMFIRE SCF125-100-300 applies this design to the 300–750 GPM range with UL Listing and FM Approval per NFPA 20.
UL (Underwriters Laboratories) Listing and FM (FM Approvals) certification are two independent third-party certifications verifying that a fire pump meets the applicable standards (such as UL 448 and FM 1311). Both are widely accepted by fire protection consultants, insurers, and authorities having jurisdiction in export markets. Many projects specify either one; some require both. The SCF125-100-300 carries both UL Listing and FM Approval, giving maximum flexibility for consultant approval and insurance acceptance on international projects.
The SCF125-100-300 covers rated flows of 300, 400, 450, 500, and 750 GPM, with pressure ratings from 78 to 279 PSI (head 84–148 m). At the 450 GPM duty point, 50Hz operation (2980 RPM) delivers 147–203 PSI while 60Hz operation (3550 RPM) reaches up to 272 PSI. Driver options span ODP/TEFC electric motors from 100 to 200 HP and NM4/NM6 series diesel engines from 94 to 192 HP. The full selection table and performance curves for each flow/pressure/speed combination are available on request.
Match the pump to your site power supply. Most of Africa (including Ghana, Kenya, and Nigeria), the Middle East, Asia, and Europe use 50Hz grids, where the SCF125-100-300 runs at 2980 RPM. The Americas and a few other territories use 60Hz, where the pump runs at 3550 RPM. The same UL/FM certified pump model serves both — only the rated speed, pressure envelope, and driver selection differ. If your site has unreliable or no mains power, a diesel engine drive (rated at 2950 RPM, with reduced-speed 2200 RPM selections for lower-pressure duties) provides an independent backup per NFPA 20.
Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off, pressure must not exceed 140% of rated. NMFIRE engineering can verify your duty point against the SCF125-100-300 selection table and issue a project-specific performance curve for consultant approval.
Horizontal split case pumps are the most common fire pump type: easy to service in place, and suitable for medium to high flow duties (the SCF125-100-300 covers 300–750 GPM with pressure up to 279 PSI). End suction pumps offer a simple, economical layout for lower duties. Vertical inline pumps have the most compact footprint for space-limited plant rooms and retrofits. All three types are available from NMFIRE with UL Listed and FM Approved certification per NFPA 20. Selection depends on project flow, available space, and maintenance strategy.
Yes. The same UL/FM certified pump is available with ODP or TEFC electric motor drive (100–200 HP, 50Hz or 60Hz) or with NM4/NM6 series diesel engine drive (94–192 HP at 2950 RPM). Diesel drive is the NFPA 20 preferred choice where a backup power source is required — common on sites with unreliable grids. Reduced-speed 2200 RPM diesel selections are also available for lower-pressure duties (80–101 PSI at 450 GPM). Engine power is verified per site altitude and ambient temperature per NFPA 20 derating rules, and the diesel package includes engine controller, batteries, and cooling matched to the duty point.
Yes. The SCF125-100-300 is one of the highest-pressure models in the SCF split case range, reaching 279 PSI at 60Hz (3550 RPM). At the 450 GPM duty point it delivers up to 272 PSI on 60Hz and up to 203 PSI on 50Hz — sufficient for high-rise standpipe systems. For sustained duties at the top of the pressure envelope, NMFIRE engineering confirms the impeller, casing, and driver selection against the certified performance curve and issues the project-specific factory test report for consultant approval.
Most African countries have no domestic fire pump manufacturing standard; NFPA 20 is the reference standard most commonly adopted by fire consultants, insurers, and regulators across Ghana, Kenya, Nigeria, Tanzania, South Africa, and the wider region. UL Listing and FM Approval are the recognized third-party certifications for imported fire pumps. African grids are 50Hz, so the SCF125-100-300 2980 RPM (50Hz) configuration is the standard selection for these markets. NMFIRE supplies NFPA 20-compliant, UL/FM certified fire pumps and project documentation suited to consultant approval processes in these regions.
A 450 GPM fire pump is a typical duty for ordinary and extra hazard occupancies requiring substantial capacity: shopping malls and commercial complexes (a frequent requirement in Ghana and across Africa), hospitals and institutional buildings, hotels, mid- and high-rise buildings, and industrial plants. With pressure capability up to 279 PSI, the SCF125-100-300 also covers standpipe systems in taller buildings. For still higher flow duties, the same pump model extends to 750 GPM, and NMFIRE offers the larger SCF200 series beyond that.
The SCF125-100-300 pump unit itself comprises the horizontal split case pump and its electric motor or diesel engine. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL/FM listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.
Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The SCF125-100-300 horizontal split case model is UL Listed and FM Approved. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.
Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.
NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.