-
Hany SamyI do not find what I can say and I do not know how to thank you. It was a great week with you and it was one of the best times I ever had. your boss is excellent and the factory is very good I'll miss you all I miss you so much Thank you Hany samy
-
HazelThank you very much for the training and for being generous hosts. We have learned a lot and will be putting our knowledge into good use. Regarding the specs for our sample model, we’ll get back to you once we have gathered more information. Again, thank you for accommodating us in the training J
-
WenThanks for the hospitality during our visit to your company. We are waiting for your revise offer with inclusive shipping cost. Thanks.
Red Color 2000gpm Diesel Engine Driven Fire Pump Set Used In Building
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xCertification | UL/FM/NFPA20 | Flow | 454m³/h |
---|---|---|---|
Engine | NM FIRE/DEMAAS | Color | Red |
Head | 135-170PSI | Application | Buildings |
High Light | diesel driven fire pump,diesel powered fire pump |
Fm Approved 2000gpm Diesel Engine Driven Fire Pump Set Used In Building
UL / FM 2000gpm @ 135-170PSI Diesel Engine Driven Fire Pump Set With Single Stage Fire Water Pump Used In Building
A split case pump is a type of centrifugal pump in which the pump’s casing is split into two separate chambers. This type of pump is different from an inline pump or an end suction pump in which the discharge nozzle and the suction nozzle are both included in one chamber.
There are two main types of the split case pump. When the casing is split along a vertical plane with respect to the impeller, it is referred to as a vertical split case pump. When the casing is split along a horizontal plane, it is referred to as a horizontal split case pump. The later type of casing design is more economical in applications that require significantly higher flows, and its impeller can be supported using bearings on two sides, which is an advantage for larger, higher flow pumps.
Split case fire pumps are specifically designed and tested for fire service application around the world including:
Office buildings, hospitals, airports, manufacturing facilities, warehouses, power stations, oil and gas industry, schools/colleges, hotels, etc.
Parameters:
HEAD | PUMP MODEL | SPEED | MAX SHAFT POWER | DIESEL ENGINE DRIVER | ||||||||
PSI | FEET | METER | RPM | HP | KW | NMFIRE-UL | HP | KW | DE MAAS-FM | HP | KW | |
135 | 312 | 95 | SCF200-150-460 (8x6") |
1800 (60HZ) |
286 | 213.1 | NM6-128 | 472 | 352 | DF12TiH-F | 338 | 252 |
140 | 324 | 98 | 298 | 222.0 | ||||||||
145 | 335 | 102 | 310 | 231.0 | ||||||||
150 | 347 | 106 | 322 | 239.9 | ||||||||
155 | 358 | 109 | 334 | 248.8 | ||||||||
160 | 370 | 113 | 345 | 257.0 | ||||||||
165 | 381 | 116 | 357 | 266.0 | ||||||||
170 | 393 | 120 | 369 | 274.9 |
Advantage:
CNP NM FIRE is the world's first manufacturer who have both UL/FM certification for fire pump and the fire fighting diesel engine,also the only one who has the UL Witness laboratory in Asia for pump and fire fighting diesel engine.
UL certification represents the world's highest technical standards of fire certification,but also means that certified fire products must withstand the most extreme,harsh test process,the purpose of certification designed to verify whether the product meets the performance,safety and quality requirements,so as to achieve the purpose of property protection.