HazelThank you very much for the training and for being generous hosts. We have learned a lot and will be putting our knowledge into good use. Regarding the specs for our sample model, we’ll get back to you once we have gathered more information. Again, thank you for accommodating us in the training J
-
WenThanks for the hospitality during our visit to your company. We are waiting for your revise offer with inclusive shipping cost. Thanks.
Water Use Horizontal End Suction Centrifugal Pumps 300GPM /125PSI FM Approved
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xCertification | UL/FM/NFPA20 | Flow | 300GPM |
---|---|---|---|
Pump | CNP NM FIRE | Casing: | Ductile Cast Iron |
Impeller | Bronze | Color | Red |
Water Use UL Listed Centrifugal End Suction Fire Pumps 300GPM @ 125PSI FM Approved
The appeal of an end suction pump is usually its lower initial cost. If the pump can perform at a given rating and pressure, then this type of pump is adequate. If diesel-engine driven, another advantage is the ability to have an engine parallel and close to a wall (assuming proper air venting is considered). This can save space in a mechanical room piping layout.
The removal of the impeller requires pulling the impeller back out of the casing, which requires removal of the motor to provide space for this to happen. Often this is a more difficult procedure for those maintaining the pump.
Parameters:
HEAD | PUMP MODEL | SPEED | MAX SHAFT POWER | |||
PSI | FEET | METER | RPM | HP | KW | |
125 | 288 | 88 | ESF65/26 (2.5"x2") |
2980 (50Hz) |
60 | 44.7 |
NFPA20, UL, FM, EN12845,CCCF
How it Works:
The end suction centrifugal pump normally contains a single impeller and a spiral like casing. The fluid that is being pumped moves along the impeller’s vanes, which increases the fluid’s velocity. From there the fluid is moved into the spiral like casing, where the high velocity is transformed into high pressure by a diffusion process.
Performance Ranges:
UL:
|
Q: 100-750GPM | H:100-145PSI |
FM:
|
Q: 100-750GPM | H:100-145PSI |
CCCF:
|
Q:5-150L/S | H:0.40-1.6Mpa |
NFPA20:
|
Q: 100-2250GPM | H:60-230PSI |
Product Type:
End Suction Fire Pump
NFPA20 Package
Advantage:
NM Fire is the firt member of NFPA from Chinese pump manufacturers. The production of fire pump groups is strictly in accordance with NFPA20, production process and performance testing also meet the requirement of ISO9001, some kinds of products have got APSAD (France), UL,FM and CCCF certificates.
We are the only enterprise in China that obtained not only UL and FM certificates, but CCCF as well, also the firt company in the world who was authorized by UL CCIC as witness testing center for both fire pump and fire fighting engines.