logo
Wuhan Spico Machinery & Electronics Co., Ltd.
products
products
Home > products > > VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems

VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems

Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL

Model Number: VIF80/20

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Plywood

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

VIF80/20 NFPA 20 Pump

,

VIF80/20 UL Listed Pump

,

VIF80/20 500 GPM Pump

Application:
Fire Fighting
Power Source:
Electric Motor / Diesel Engine
Pump Type:
Vertical Inline
Connection Size:
2 Inch To 12 Inch
Speed:
1450 / 2900 RPM
Material:
Cast Iron / Stainless Steel
Application:
Fire Fighting
Power Source:
Electric Motor / Diesel Engine
Pump Type:
Vertical Inline
Connection Size:
2 Inch To 12 Inch
Speed:
1450 / 2900 RPM
Material:
Cast Iron / Stainless Steel
VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems
VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems
UL LISTED  |  NFPA 20 COMPLIANT  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE VIF80/20 is a UL Listed vertical inline fire pump covering 250–500 GPM for NFPA 20 fire protection systems. Its vertical inline design mounts the TEFC electric motor directly above the pump, with suction and discharge on the same centerline — delivering full performance in a compact, space-saving footprint that fits plant rooms, rooftops, and retrofit sites where horizontal split case or end suction pumps cannot be installed.

The VIF series is engineered for commercial buildings, industrial facilities, warehouses, and infrastructure projects where available space is limited. A close-coupled, space-saving construction with top-pullout access allows impeller and seal service without disturbing the piping, reducing maintenance downtime. The pump installs directly in-line with existing piping runs — no foundation pit or separate bearing frame required.

Manufactured to NFPA 20 requirements with UL Listing, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.

VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems

Key Specifications

Product Type: Vertical Inline Fire Pump
Model: VIF80/20
Certification: UL Listed
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 250-500 GPM
Pressure Range: 70-157 PSI
Driver Type: Electric Motor (TEFC)
Pump Type: Vertical Inline
Application: Commercial / Industrial / Infrastructure

Pump Range Overview
Parameter Specification
Rated Flow 250 / 300 / 400 / 450 / 500 GPM
Pressure Range 70 – 157 PSI
Head Range 64 – 110 m
Pump Speed 2980 / 3550 RPM
Driver TEFC Electric Motor, 30 – 100 HP
Certifications UL Listed
Example Duty Point Configuration
Parameter Value
Pump Model VIF80/20
Rated Flow 500 GPM
Rated Pressure 150 PSI
Max Shaft Power 66 kW / 88 HP
Pump Speed 3550 RPM
Motor Model JP405TS F-TXC405TS100U2B (100 HP TEFC)
Controller Tornatech
Key Features
  • UL Listed fire protection solution
  • Compact vertical inline design — minimal footprint, ideal for space-limited plant rooms and retrofits
  • Designed and tested per NFPA 20 requirements
  • TEFC electric motor drive (30–100 HP) — sealed enclosure, low maintenance
  • Wide flow and pressure range (250-500 GPM, 70-157 PSI)
  • Motor enclosure and ambient temperature selected per site conditions
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
Applications

Commercial & Mid-Rise Buildings

Reliable emergency water supply for sprinkler systems, standpipes, and fire suppression in offices, hotels, retail centers, and residential buildings.

Manufacturing & Warehousing

Suitable for factories, logistics centers, and warehouses requiring dependable sprinkler system support at moderate flow duties.

Data Centers & Infrastructure

Compact inline configuration fits the tight plant rooms of data centers, metro stations, airports, and parking structures.

Space-Limited & Retrofit Installations

Vertical inline design installs directly in the pipe run — ideal for rooftops, basements, and retrofit projects where horizontal split case pumps cannot be accommodated.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required engine power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Wear Ring Bronze
Packing Sleeve SS304
Packing Gland SS304
Packing Ring SS304
Seal Gland Packing

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

VIF Design & Maintenance Features
Vertical Inline Fire Pump — Design Advantages:
Inline piping — suction and discharge on the same centerline, fitting existing pipe runs with minimal layout change
Close-coupled, space-saving — motor directly mounted on the pump, no separate bearing frame or foundation pit; ideal for plant rooms and retrofit
Top pull-out — impeller and seal accessible by lifting the motor, without disturbing the piping
TEFC motor — sealed, fan-cooled enclosure as standard (30–100 HP for the VIF80/20 range), suited to hot, dusty or hazardous areas
Single mechanical seal — standard, easy to source spare
Project Submittal & Technical Documents

Fire protection projects often require technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Standard Documents:

  • Factory Test Report — including the pump performance curve
  • Pump Drawings — outline and dimensional drawings

For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss.


VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems

FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

What is a vertical inline fire pump, and why choose one for a compact plant room?

A vertical inline fire pump has its electric motor mounted directly above the pump, with suction and discharge nozzles on the same vertical centerline. This close-coupled configuration needs no separate bearing frame or foundation pit, so the pump installs straight into the piping run and occupies a minimal footprint. It is the preferred choice for compact plant rooms, rooftops, basements, and retrofit projects where a horizontal split case pump would not fit. The NMFIRE VIF80/20 delivers 250–500 GPM in this space-saving inline format, UL Listed per NFPA 20.

What is the difference between vertical inline, horizontal split case, and end suction fire pumps?

Horizontal split case pumps are bidirectional and easier to maintain (the upper casing half can be removed without disturbing piping), typically used for medium to high flow duties. End suction pumps offer a simple, economical layout for lower duties. Vertical inline pumps have the most compact footprint — the motor sits directly on the pump and the nozzles align with the pipe run — making them ideal where space is limited. All three types are available from NMFIRE with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.

What is the flow and pressure range of the VIF80/20?

The VIF80/20 covers rated flows of 250, 300, 400, 450, and 500 GPM, with pressure ratings from 70 to 157 PSI (head 64–110 m). Pump speed options are 2980 and 3550 RPM depending on the duty point. Each flow/pressure combination is driven by a matched TEFC electric motor from 30 to 100 HP. Typical selections include 500 GPM at 109–150 PSI and 400 GPM at 70–154 PSI; the full selection table and performance curves are available on request.

How do I size a vertical inline fire pump per NFPA 20?

Sizing starts from the hydraulic calculations of the sprinkler or standpipe system: the required flow (GPM) at the most demanding point plus hose stream allowance, and the pressure needed to overcome elevation, friction losses, and required residual pressure at the topmost outlet, minus available municipal supply pressure. The selected pump must then meet the NFPA 20 performance criteria: at 150% of rated flow, discharge pressure must be ≥65% of rated pressure; at shut-off (zero flow), pressure must not exceed 140% of rated. NMFIRE engineering can verify the duty point against the VIF80/20 selection table and issue a project-specific performance curve for consultant approval.

Can the VIF80/20 be installed directly in-line with existing piping?

Yes. The suction and discharge flanges are on the same centerline, so the pump connects straight into a vertical pipe run with minimal layout change and no foundation pit. Flanged connection sizes are matched to the system piping for each configuration — exact dimensions are shown in the pump outline drawings. As with any fire pump, suction conditions (positive suction head, straight suction piping, and velocity limits) must be verified per NFPA 20 before installation.

What package options are available for the VIF80/20?

The VIF80/20 pump unit itself comprises the vertical inline pump and its TEFC electric motor. For projects requiring a complete fire pump system, NMFIRE can configure packages that add a UL Listed fire pump controller, a jockey pump for pressure maintenance, and a pressure relief valve where required. Delivery options include conventional plant room installation, a skid-mounted fire pump system with pre-piped pump and jockey pump on a common base, and a fully containerized fire pump station pre-assembled for plug-and-play site connection. Package scope is configured per NFPA 20 and project requirements.

What applications suit a 500 GPM vertical inline fire pump?

A 500 GPM inline fire pump is a common duty for light hazard and ordinary hazard occupancies: mid-rise commercial and residential buildings, hotels, retail centers, office buildings, parking structures, data centers, and single-zone warehouses. The VIF80/20's compact vertical format is particularly advantageous where the fire pump room is small or the pump must be retrofitted into an existing riser. For higher flow duties (750–1500 GPM), NMFIRE also offers larger vertical inline and horizontal split case models.

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements. The VIF80/20 vertical inline model is UL Listed. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

Can you provide CAD drawings and pump performance curves?

Yes. Factory test reports including pump performance curves, together with pump outline and dimensional drawings, are provided as standard technical documents. For skid-mounted or containerized packages, or any other document requirements, please contact us to discuss. Third-party witness testing at our fire pump test facility can also be arranged per project requirements.

Technical Guides & Resources
  • NFPA 20 Fire Pump Selection Guide — How to select the right pump for your project
  • Diesel vs Electric Fire Pump — Driver selection criteria per NFPA 20
  • Fire Pump Testing Guide — Understanding factory and field acceptance tests
  • VIF Design & Maintenance Guide — Inline configuration and maintenance access
  • NFPA 20 Performance Requirements — 150% flow and shut-off pressure criteria explained
  • Fire Pump Package Components — Complete guide to pump, controller, jockey pump, relief valve
  • Skid-Mounted & Containerized Fire Pump Stations — Pre-assembled delivery options

VIF80/20  UL Listed Vertical Inline Fire Pump  250–500 GPM Designed For NFPA 20 Fire Protection Systems


NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.

Tags:

Similar Products