Product Details
Payment & Shipping Terms
NMFIRE series is a UL Listed vertical inline fire pump designed for NFPA 20 fire protection systems. Its vertical inline design mounts the electric motor directly above the pump, with suction and discharge on the same centerline — delivering full performance in a compact footprint that fits pump rooms, rooftops, and retrofit sites where horizontal split case or end suction pumps cannot be installed.
The VIF series is engineered for commercial buildings, industrial facilities, warehouses, and infrastructure projects where available space is limited. A close-coupled, space-saving construction with top-pullout access allows impeller and seal service without disturbing the piping, reducing maintenance downtime.
Manufactured to NFPA 20 requirements and UL Listed, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure.
![]()
Product Type: Vertical Inline Fire Pump
Model: VIF150/32
Certification: UL Listed
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 1000-1500 GPM
Pressure Range: 46-188 PSI
Driver Type: Electric Motor
Pump Type: Vertical Inline
Application: Commercial / Industrial / Infrastructure
| Parameter | Specification |
|---|---|
| Rated Flow | 1000 / 1250 / 1500 GPM |
| Pressure Range | 46 – 188 PSI |
| Head Range | 35 – 132 m |
| Pump Speed | 1760 / 2980 RPM |
| Driver | Electric Motor |
| Certifications | UL Listed |
| Rotation | CW |
| Parameter | Value |
|---|---|
| Pump Model | VIF150/32 |
| Rated Flow | 1500 GPM |
| Rated Pressure | 150 PSI |
| Max Shaft Power | 219 HP |
| Pump Speed | 2980 RPM |
| Motor Model | F-TXC449TS250U2B V1 |
| Controller | Tornatech |
High-Rise Buildings
Reliable emergency water supply for sprinkler systems, standpipes, and fire suppression in commercial towers, hotels, and residential buildings.
Oil & Gas Facilities
Designed for refineries, petrochemical plants, fuel storage terminals, and industrial environments requiring dependable fire protection.
Manufacturing & Warehousing
Suitable for factories, logistics centers, and warehouses requiring high-capacity sprinkler system support.
Space-Limited Installations
Compact vertical inline design fits tight pump rooms, rooftops, and retrofit projects where horizontal split case pumps cannot be accommodated.
Need Technical Data & Pricing?
Get project-specific pump selection, performance curves, and quotation within 24 hours.
Contact: Tarik@nmfirepump.com
NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.
Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:
Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:
Critical components are processed through precision CNC machining. Quality control includes:
Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:
Our dedicated fire pump test bench enables:
| Component | Standard Material |
|---|---|
| Casing | Ductile Cast Iron |
| Impeller | SS304 |
| Wear Ring | Bronze |
| Packing Sleeve | SS304 |
| Packing Gland | SS304 |
| Packing Ring | SS304 |
| Seal | Gland Packing |
For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.
Fire protection projects often require complete technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.
Available Documents:
For skid-mounted or containerized packages, controller layout can be included in the GA drawing upon request. For other special document requirements, please contact us to discuss.
![]()
Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements and available with UL Listed certification; FM Approved is offered on selected models. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.
Horizontal split case pumps are bidirectional and easier to maintain (the upper casing can be removed without disturbing piping), typically used for medium to high flow. Vertical inline pumps have a compact vertical design that fits tight pump rooms and rooftops where horizontal pumps cannot be installed, with the motor directly coupled above the pump. Both types are available with UL Listed certification per NFPA 20. Selection depends on project flow, available space, and installation constraints.
NMFIRE offers horizontal split case, end suction, vertical inline, and vertical turbine pump types. The VIF150/32 vertical inline model is UL Listed and electric motor driven as standard; other types are available with UL Listed and FM Approved certification per NFPA 20. Vertical turbine pumps are suited to deep well and wet pit applications. Complete packages include fire pump, motor/engine driver, controller, jockey pump, relief valve, and standard accessories per NFPA 20.
Yes. Technical documents including General Arrangement (GA) drawings, pump performance curves, technical datasheets, motor datasheets with enclosure selection, controller datasheets, factory test reports, and installation manuals are available for project submission. Our engineering team provides project-specific submittal packages.
Yes. Factory inspection and third-party witness testing can be arranged according to project requirements. Our dedicated fire pump test facility enables accurate flow measurement, pressure monitoring, and complete performance curve generation. Third-party inspection agencies are welcome to participate in factory testing per project requirements.
For electric motor driven fire pumps, altitude does not reduce motor power output, so no altitude derating is required. However, motor enclosure and insulation class are selected for the installation environment — TEFC (Totally Enclosed Fan Cooled) is standard for NMFIRE VIF packages and is suited to high-temperature, dusty, or hazardous areas. NMFIRE engineering selects the motor rating based on actual site conditions to ensure reliable starting and operation at the specified duty point; supply voltage, phase, and frequency are confirmed at order.
NMFIRE offers single electric, 1 electric + 1 diesel, and 2 electric configurations, as well as containerized fire pump houses for pre-assembled, plug-and-play installation. Material options include standard fresh water, corrosion resistant (stainless steel 316L), and seawater service (duplex stainless steel). Controller options include UL Listed fire pump controllers compatible with the selected driver. Configuration is selected per NFPA 20 and project requirements.
NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.
![]()