Product Details

Place of Origin: China

Brand Name: NMFIRE

Certification: NFPA20 UL FM

Model Number: SCF125-80-250

Document: DEMANDS INFO FORM Tarik.pdf

Payment & Shipping Terms

Minimum Order Quantity: 1

Delivery Time: 80 days

Payment Terms: L/C,T/T

Supply Ability: 80 days

Get Best Price
Highlight:

UL/FM Horizontal Split Case Fire Pump

,

SCF125-80-250 Horizontal Split Case Fire Pump

Flow Range:
300 GPM / 400 GPM / 450 GPM / 500 GPM / 750 GPM
Pressure Range:
115-147PSI
Driver Type:
Diesel Engine/ Motor
Frequency:
50Hz/60Hz
Pump Casing Material:
Ductile Cast Iron
Impeller Material:
SS304
Flow Range:
300 GPM / 400 GPM / 450 GPM / 500 GPM / 750 GPM
Pressure Range:
115-147PSI
Driver Type:
Diesel Engine/ Motor
Frequency:
50Hz/60Hz
Pump Casing Material:
Ductile Cast Iron
Impeller Material:
SS304
SCF125-80-250 UL/FM Horizontal Split Case Fire Pump 300–750 GPM Designed For NFPA 20 Fire Protection Systems
SCF125-80-250  UL/FM Horizontal Split Case Fire Pump  300–750 GPM Designed For NFPA 20 Fire Protection Systems
UL LISTED  |  FM APPROVED  |  NFPA 20 COMPLIANT  |  ISO 9001  |  Factory Performance Tested
Product Overview

NMFIRE UL/FM Certified Diesel Engine Driven Fire Pump is designed to provide reliable emergency water supply for automatic sprinkler systems, standpipe systems, and industrial fire protection applications. Manufactured according to NFPA 20 requirements, this diesel fire pump package provides stable hydraulic performance under critical fire conditions where reliable backup power is required.

The system combines a high-performance fire pump, diesel engine driver, UL/FM listed controller, and accessories to deliver dependable operation for commercial buildings, industrial facilities, oil & gas projects, and infrastructure applications. With UL Listed and FM Approved certification, NMFIRE diesel engine driven fire pumps are suitable for projects requiring internationally recognized fire protection standards.

Per NFPA 20, each pump is factory performance tested to verify shut-off pressure (not exceeding 140% of rated pressure), rated flow and pressure, and 150% rated flow at no less than 65% of rated pressure. Diesel engine power is derated for site altitude and ambient temperature to ensure sufficient standby power at the specified duty point.

SCF125-80-250  UL/FM Horizontal Split Case Fire Pump  300–750 GPM Designed For NFPA 20 Fire Protection Systems

Key Specifications

Product Type: Horizontal Split Case Fire Pump
Model: SCF125-80-250
Certification: UL Listed / FM Approved
Design Standard: NFPA 20 (Standard for Installation of Stationary Pumps for Fire Protection)
Flow Range: 300-750 GPM
Pressure Range: 41-183 PSI
Driver Type: Diesel Engine / Motor
Pump Type: Horizontal Split Case
Application: Commercial / Industrial / Infrastructure

Pump Range Overview
Parameter Specification
Rated Flow 300 / 400 / 450 / 500 / 750 GPM
Pressure Range 41 – 183 PSI
Head Range 29 – 128 m
Pump Speed 2200 / 2950 / 2980 / 3550 RPM
Driver Diesel Engine / Motor
Certifications UL Listed / FM Approved
Rotation CW / CCW
Example Duty Point Configuration
Parameter Value
Pump Model SCF125-80-250
Rated Flow 750 GPM
Rated Pressure 150 PSI
Max Shaft Power 72 kW / 92 HP
Pump Speed 3550 RPM
Engine Model F-TDC 365TS100U2B / F-TXC 405TS100U2B
Controller Tornatech
Key Features
  • UL/FM certified fire protection solution
  • Designed and tested per NFPA 20 requirements
  • Reliable diesel engine backup power source
  • Wide flow and pressure range (300-750 GPM, 41-183 PSI)
  • Complete package: pump, engine, controller, jockey pump, relief valve
  • Altitude and temperature derating calculated per site conditions
  • Factory performance tested before shipment
  • Engineering documents available for project submittal
  • Third-party witness testing supported per project requirements
Applications

High-Rise Buildings

Reliable emergency water supply for sprinkler systems, standpipes, and fire suppression in commercial towers, hotels, and residential buildings.

Oil & Gas Facilities

Designed for refineries, petrochemical plants, fuel storage terminals, and industrial environments requiring dependable fire protection.

Manufacturing & Warehousing

Suitable for factories, logistics centers, and warehouses requiring high-capacity sprinkler system support.

Marine & Offshore

Special material configurations for marine environments and seawater fire protection applications.

Need Technical Data & Pricing?

Get project-specific pump selection, performance curves, and quotation within 24 hours.

Contact: Tarik@nmfirepump.com


ENGINEERING & MANUFACTURING DETAILS
For technical review and project submittal — click to expand

Manufacturing & Engineering Design

NMFIRE fire pump packages are manufactured through advanced hydraulic design, precision machining, and strict quality control processes to ensure reliable operation in critical fire protection applications.

CFD Analysis & 3D Hydraulic Design

Advanced Computational Fluid Dynamics (CFD) analysis and 3D hydraulic design are applied to optimize internal flow performance:

  • Improved hydraulic efficiency
  • Reduced hydraulic losses
  • Lower required engine power
  • Stable flow and pressure performance
Precision Casting Technology

Pump casing manufacturing adopts Lost Foam Casting Technology to improve surface quality and hydraulic performance. Manufacturing capabilities include:

  • CNC processed metal patterns
  • Automatic molding line
  • Automatic sand processing production line
  • Intermediate frequency melting furnace
  • VOD refining furnace
  • Precision wax casting technology
Machining & Component Quality Control

Critical components are processed through precision CNC machining. Quality control includes:

  • Impeller machining and dimensional inspection
  • Shaft machining and runout verification
  • Assembly alignment verification
  • Dynamic balancing test for all rotating components
Factory Performance Testing

Each NMFIRE fire pump package undergoes factory performance verification before delivery per NFPA 20 requirements. Testing includes:

  • Shut-off (churn) pressure testing — must not exceed 140% of rated pressure
  • Rated flow and rated pressure verification
  • 150% rated flow verification — pressure must be ≥65% of rated pressure
  • Pressure-flow curve recording (minimum 5 test points)
  • Operating parameter monitoring (vibration, temperature, noise)
Fire Pump Test Facility

Our dedicated fire pump test bench enables:

  • Accurate flow measurement via calibrated flow meter
  • Pressure monitoring at suction and discharge
  • Complete performance curve generation
  • Third-party witness testing arrangement per project requirements
NFPA 20 Acceptance Criteria:
At 150% of rated flow, discharge pressure must be ≥65% of rated pressure.
At shut-off (zero flow), pressure must not exceed 140% of rated pressure.
These are mandatory pass/fail criteria per NFPA 20.
Materials & Construction
Component Standard Material
Casing Ductile Cast Iron
Impeller SS304
Shaft AISI 4340
Shaft Sleeve SS304
Seal Gland Packing
Wear Ring Bronze
Bearing SKF

For seawater service, corrosion-resistant, or other special material requirements, please contact us to discuss.

Altitude & Temperature Derating
Diesel Engine Derating per NFPA 20:
Engine nameplate power must be derated for site conditions:
• Approximately 3% power reduction per 300m (1000 ft) above sea level
• Approximately 1% power reduction per 5.5°C (10°F) above 25°C (77°F)

NMFIRE engineering calculates derating factors based on actual project site conditions to ensure the engine has sufficient standby power at the specified flow and pressure duty point.
Project Submittal & Technical Documents

Fire protection projects often require complete technical documents for consultant approval and installation. NMFIRE provides project-specific engineering support.

Available Documents:

  • General Arrangement (GA) Drawing — dimensional layout with baseplate, pump, and engine
  • Pump Performance Curve — factory test curve with rated, 150% flow, and shut-off points
  • Technical Datasheet — complete pump specifications per project requirements
  • Diesel Engine Datasheet — engine specs with altitude/temperature derating calculation
  • Controller Datasheet — UL/FM listed fire pump controller specifications
  • Factory Test Report — witnessed performance test results
  • Installation, Operation & Maintenance (IOM) Manual
  • UL/FM Certification Documents

For skid-mounted or containerized packages, controller layout can be included in the GA drawing upon request. For other special document requirements, please contact us to discuss.

SCF125-80-250  UL/FM Horizontal Split Case Fire Pump  300–750 GPM Designed For NFPA 20 Fire Protection Systems


FREQUENTLY ASKED QUESTIONS
Technical questions & answers — click to expand

Are NMFIRE fire pumps compliant with NFPA 20?

Yes. NMFIRE fire pump packages are designed according to NFPA 20 requirements and available with UL Listed and FM Approved certification options. Each pump is factory performance tested per NFPA 20 including shut-off pressure verification (max 140% of rated), rated flow testing, and 150% rated flow verification at no less than 65% of rated pressure.

What is the difference between horizontal split case and end suction fire pumps?

Horizontal split case pumps are bidirectional, easier to maintain (the upper casing half can be removed without disturbing piping connections), and typically used for medium to high flow applications. End suction pumps are more compact, suitable for space-limited installations, and generally more cost-effective for lower flow ranges. Both types are available with UL Listed and FM Approved certification per NFPA 20. Selection depends on project flow requirements, available space, and budget considerations.

What pump types are available for the diesel driven configuration?

NMFIRE offers horizontal split case and end suction pump types for diesel engine driven configurations. Vertical turbine pumps are also available for wet pit applications. All pump types are available with UL Listed and FM Approved certification. Complete packages include fire pump, diesel engine, controller, jockey pump, relief valve, fuel tank, and standard accessories per NFPA 20.

Can you provide CAD drawings and pump performance curves?

Yes. Technical documents including General Arrangement (GA) drawings, pump performance curves, technical datasheets, engine datasheets with derating calculations, controller datasheets, factory test reports, and installation manuals are available for project submission. Our engineering team provides project-specific submittal packages.

Do you support third-party inspection and witness testing?

Yes. Factory inspection and third-party witness testing can be arranged according to project requirements. Our dedicated fire pump test facility enables accurate flow measurement, pressure monitoring, and complete performance curve generation. Third-party inspection agencies are welcome to participate in factory testing per project requirements.

Is altitude and temperature derating considered for diesel engines?

Yes. Per NFPA 20 requirements, diesel engine power must be derated for altitude and ambient temperature at the installation site. Typically, engine power is reduced by approximately 3% per 300 meters (1000 ft) above sea level, and 1% per 5.5°C (10°F) above 25°C (77°F). NMFIRE engineering team calculates derating factors based on actual project site conditions to ensure the engine has sufficient standby power at the specified flow and pressure duty point.

What configurations are available for the fire pump package?

NMFIRE offers single diesel, single electric, 1 electric + 1 diesel, 2 electric, and 2 diesel configurations. Material options include standard fresh water, corrosion resistant (stainless steel 316L), and seawater service (duplex stainless steel). Controller options include UL/FM listed diesel fire pump controllers compatible with the selected engine model. Containerized fire pump houses are also available for projects requiring pre-assembled, plug-and-play installation.

SCF125-80-250  UL/FM Horizontal Split Case Fire Pump  300–750 GPM Designed For NFPA 20 Fire Protection Systems


NMFIRE — Professional fire pump manufacturer specializing in UL Listed and FM Approved fire protection systems. Designed per NFPA 20 for global commercial, industrial, and infrastructure projects.
UL® and FM® are registered trademarks of their respective owners.

Tags:

Similar Products