• Wuhan Spico Machinery & Electronics Co., Ltd.
    Hany Samy
    I do not find what I can say and I do not know how to thank you. It was a great week with you and it was one of the best times I ever had. your boss is excellent and the factory is very good I'll miss you all I miss you so much Thank you Hany samy
  • Wuhan Spico Machinery & Electronics Co., Ltd.
    Hazel
    Thank you very much for the training and for being generous hosts. We have learned a lot and will be putting our knowledge into good use. Regarding the specs for our sample model, we’ll get back to you once we have gathered more information. Again, thank you for accommodating us in the training J
  • Wuhan Spico Machinery & Electronics Co., Ltd.
    Wen
    Thanks for the hospitality during our visit to your company. We are waiting for your revise offer with inclusive shipping cost. Thanks.
Contact Person : Kathy Wong
Phone Number : 008618627949609
Whatsapp : +008618986068523

Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller

Place of Origin China
Brand Name CNP NM FIRE
Certification UL Listed
Model Number ESF50/20 (2.5"x2")
Minimum Order Quantity 1set
Price Negotiation
Packaging Details Export Packing
Delivery Time 60 Days
Payment Terms L/C, T/T

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
CAPACITY 250GPM HEAD 110PSI
Driving Mode DIESEL ENGINE DRIVER Controller Tornatech (UL/FM)
Color Red Standar UL
Leave a Message
Product Description

UL End Suction Pump , Diesel Engine Fire Pump 250gpm@110psi

 

 

Fire Pumps are used to supply water for automatic sprinkler systems, standpipes or fire hydrants. NFPA No. 20 classifies fire pumps as split case, vertical turbine, end suction, or In-Line design. In-Line fire pumps have capacities of 50, 75, 100, 150, 200, 250, 300,400, 450, 500, and 750 GPM; End Suction pumps are rated for 100, 200, 250, 300, 400,450, 500, and 750 GPM; Split case and vertical turbine fire pumps are rated 150, 200, 300, 450, 500, 750, 1000, 1250, 1500, 2000,3000, 3500, 4000, 4500, and 5000 GPM.All fire pumps are rated at 40 pounds per square inch or more of boost.

Fire Pumps of the type described shall meet the following basic requirements: 

1.Each pump is to be tested hydrostatically

for not less than 5 minutes. The test pressure is to be not less than 1.5 times the maximum working pressure of the pump, but in no case less than 250 psi (1724 kPa).

2.A pump shall develop not less than 65 percent of rated total head when discharging at 1.5 times rated capacity.The maximum net pressure for a fire pump shall not exceed 140 percent of rated head.

3.The maximum pump brake horsepower shall not exceed the HP rating its driver, including service factor.
  • Product Details
Diesel Engine Pump Set( Heat Exchanger) UL LISTED
NM Fire End Suction Pump
Model
ESF50/26
This Diesel Engine Group includes the pump(inlet & outlet gauges) Diesel Engine, Commonbase, Silencer, ,Batteries,Flexible exhaust connector, Control System, Coupling (non-listed), Cooling System.




Please contact me if you need Fuel tank, Main relief valve,Waste corn or other accessories.
Capacity
250GPM
Head
111SI
RPM
2980rpm
Material:
 
Casing
Ductile Cast iron
Impeller
Bronze
Shaft
SS420
Seal
Gland packing
Wear ring
Bronze
Bearing
SKF
Engine: NM FIRE (UL)
Model:
NM4-90
Controller : Tornatech (UL/FM)
Model:

 

 

The above models are used for 250GPM@110PSI  DIESEL ENGINE DRIVER 60HZ 208V.

Please contact us if you have any other requirements.

Thanks

Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 0Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 1Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 2

  • CERTIFICATE

 

Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 3

 

  • NMFIRE 2018 International Training Conference

Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 4

 

  • End suction Pump Model Chart

 

Rated Capacity PUMP MODEL(UL) Rated Net Pressure Range, Approx. Speed, Impeller Diameter, mm.
GPM (US) PSI RPM Max Min
50 ESF40/20 76-111 2980 225 190
50 ESF40/20 108-157 3550 225 190
100 ESF40/20 72-109 2980 225 190
100 ESF40/26 100-138 2980 264 225
200 ESF50/20 72-99 2980 225 195
200 ESF50/20 102-142 3550 225 195
200 ESF50/26 105-140 2980 264 230
250 ESF50/20 69-99 2980 225 195
250 ESF50/20 101-141 3550 225 195
250 ESF50/26 99-136 2980 264 230
250 ESF65/20 113-152 3550 225 195
250 ESF65/20 86-107 2980 225 210
250 ESF65/26 119-147 2980 264 245
300 ESF65/20 112-152 3550 225 195
300 ESF65/20 86-107 2980 225 210
300 ESF65/26 119-147 2980 264 245
400 ESF65/20 108-150 3550 225 195
400 ESF65/20 83-104 2980 225 210
400 ESF65/26 119-141 2980 264 245
450 ESF65/20 105-148 3550 225 195
450 ESF65/20 80-102 2980 225 210
450 ESF65/26 114-138 2980 264 245
500 ESF65/20 101-145 3550 225 195
500 ESF65/20 77-99 2980 225 210
500 ESF65/26 111-135 2980 264 245
500 ESF80/20 90-100 2980 225 210
500 ESF80/20 129-142 3550 225 210
500 ESF80/26 116-138 2980 264 245
750 ESF80/20 87-98 2980 225 210
750 ESF80/20 127-142 3550 225 210
  • Five Advantages of CNP NM FIRE

  • 
    ①The late-mover advantage of products, we R&D better fire products than other Suppliers;
    
    ②Have the most complete and all series of fire pump models;
    
    ③Have listed diesel engines with self-owned brand--- NM FIRE;
    
    ④Understand the technology of fire- fighting products and fire- fighting system better than other competitors and have better services;
    
    ⑤Shorter delivery time.
    
    

    Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 5

  • FAQ

Q1.Do you have the UL-LISTED Fire Pump Sets?

Yes, We have the UL/FM and NFPA standard Fire Pump Sets.

Q2.I need your motor drive End-suction/Split-casing fire pump, what information shold I sent to you ?

Sir/Madam,you can privide the Capacity, Heed, Voltage and Frequncy,we will make the quotation for you,If you need Jockey Pump or other accessories, please tell us together.

Q3.If I need your Diesel Engine Drive End-suction/Split-casing fire pump, what information shold I sent to you ?

You can sent the Capacity Heed, Temperature and Altitude (temperature and altitude will affect the performance of diesel engines).If you need Jockey Pump or other accessories, please tell us Voltage and Frequncy or accessories together.

Q4.I need the UL/FM Vertical Tubine Fire Pump Set ,please sent me the price.

For the motor Diver Vertical Tubine Fire Pump Set: you shoul give us the Capacity, Heed, Voltage Frequncy and the tank deep.

For the Diesel Engine Drive Vertical Tubine Fire Pump Set:you should give us the Capacity, Heed and the tank deep.

If you need Jockey Pump or other accessories,please tell us together.


 
  • Service:

1. Reply within 24 hours.
2. High-quality products and the most reasonable price
3. Data and chemical technology support.

Impeller Centrifugal Pump Set With Jockey Pump UL Listed Fire Pump Tornatech controller 6