Product Details
Place of Origin: China
Brand Name: CNP NM FIRE
Certification: ISO/CCCF
Payment & Shipping Terms
Minimum Order Quantity: 1set
Price: Negotiation
Packaging Details: Export Packing
Delivery Time: 30-45 Working Days
Payment Terms: L/C, T/T
Certification:: |
ISO/CCCF |
Flow:: |
Up To 1000GPM |
Control Panel:: |
CNP NM FIRE |
Color:: |
Red |
Material: |
Stainless Steel |
Use: |
Firefighting |
Certification:: |
ISO/CCCF |
Flow:: |
Up To 1000GPM |
Control Panel:: |
CNP NM FIRE |
Color:: |
Red |
Material: |
Stainless Steel |
Use: |
Firefighting |
Multistage Booster Fire Jockey Pump With NFPA20 And GB6245 Standard 40GPM For Firefighting Application
Fire Jockey Pump Introduction:
The main purpose of the jockey pump is to maintain the water pressure within the pipes within a certain range when there is no fire so that the sprinklers do not randomly go off. The jockey pump also ensures that pressure in the pipes is maintained at normal pressure by refilling water into leaking pipes. In case of a fire break out and the pressure significantly drops, a jockey pump cannot keep up, and the low pressure will trigger the fire pump to start pumping water.
Additionally, the jockey pump prevents the fire sprinkler system from being damaged whenever the larger fire pump begins sending water through the system. If a fire system lacks a jockey pump to keep it pressurized, the system will develop relatively low pressure. This can lead to damage on the system as a result of the sudden change in pressure when the fire pump begins pumping water.
Any jockey pump consists of three components that include a motor, a controller and a pump. The two major types of jockey pumps are regenerative turbine pumps and centrifugal pumps. The centrifugal type is less energy efficient but requires minimal maintenance than a regenerative turbine pump. On the other hand, a regenerative turbine pump can generate high pressures with little power, but this can create excess pressure in the system. This therefore means that it requires more maintenance.
How To Choose:
It should be chosen so as to get into operation in a period as much as 10 minutes and bring the pressure to the desired level upon detecting a leakage that may be evident in the fire-extinguishing system.
It is selected at 1% of the nominal flow of the flow (min. 1 GPM), and at a pressure of more than 10% of the nominal pressure.
Performance Ranges:
CCCF: Q:0.25-125L/S H:0.40-2.5Mpa
NFPA20: Q: 100-1000GPM H:100-220PSI
Application:
Large hotels, hospitals , schools,office buildings,supermarkets, commercial residential buildings, metro stations, railway stations, airports, kinds of transportation tunnels, petrochemical plants, thermal power plants, terminals, oil depots, large warehouses and industrial and mining enterprises, etc.
A jockey pump is a small pump connected to a fire sprinkler system to maintain pressure in the sprinkler pipes. This is to ensure that if a fire-sprinkler is activated, there will be a pressure drop, which will be sensed by the fire pumps automatic controller, which will cause the fire pump to start.
A jockey pump is sized for a flow less than the flow to one sprinkler in order to ensure a system pressure drop. Hence a jockey pump is an important part of the fire pumps control system.
Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application. The control equipment for jockey pumps may however carry approvals.
Product Type:
NFPA20 Package
Advantage:
First-Class international technical standards
First-Class testing and inspection equipment.
NM Fire is the first member of NFPA from Chinese pump manufacturers .
The production of fire pump groups is strictly in accordance with NFPA20, production process and performance testing also meet the requirement of ISO9001, some kinds of products have got APSAD(France), UL , FM and CCCF certificates.
We are the only enterprise in China that obtained not only UL and FM certificates, but CCCF as well,also the first company in the world who was authorized by UL CCIC as witness testing center for both fire pumps and fire fighting engines.
UL certification represents the world's highest technical standards of fire certification,but also means that certified fire products must withstand the most extreme,harsh test process,the purpose of certification designed to verify whether the product meets the performance,safety and quality requirements,so as to achieve the purpose of property protection.
NM fire obtained fire diesel engine UL1247 and fire pump UL448 witnessed laboratory accreditation,fully proved that the company in terms of hardware and software strength,are to meet the
strict requirements of UL certification.