HazelThank you very much for the training and for being generous hosts. We have learned a lot and will be putting our knowledge into good use. Regarding the specs for our sample model, we’ll get back to you once we have gathered more information. Again, thank you for accommodating us in the training J
-
WenThanks for the hospitality during our visit to your company. We are waiting for your revise offer with inclusive shipping cost. Thanks.
1000GPM Horizontal Split Case Fire Pump
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xCapacity | 1000 GPM | Pressure | 180 PSI |
---|---|---|---|
Speed | 2980 RPM | Structure | Single-stage Pump |
Theory | Horizontal Split Case Centrifugal Pump | Warranty | 18 Months |
High Light | 1000GPM Horizontal Split Case Fire Pump,180PSI Horizontal Split Case Fire Pump,1000GPM Centrifugal Water Pump |
1000 GPM Horizontal Split Case Fire Pump Centrifugal Water Pump
UL/FM Fire Pump Performance Requirements:
The maximum net pressure for a fire pump shall not exceed 140 percent of rated head.
( Hs ≤ 140% x H)
Inlet pressure less than 047.7 kpa. A pump shall develop not less than 65 percent or rated
total head when discharging at 1-1/2 times rated. (H 1.5 Q ≥ H x 65%)
A test is to be conducted with a positive suction pressure sufficient to achieve the maximum
brake-horsepower(KW input)required by the pump. ( P ≥ BHP)
The shut off head shall not be less than 99% of the maximum head.
UL / FM Pump Focus on safety and reliability (short-time running)
1:Working point is different.
Fire pump :highest efficiency point is near 1.5Q
-- No cavitation, no influence on water absorption performance
-- NPSHr curve is not required
2: Matching power is different
Fire pump :
-- Matching power ensures no overload at any flow rate
3: Hydraulic design is different
Fire pump :
-- The power curve is required to have an inflection point
-- The front end of curve is flat, after 1.5Q, curve fall steep
4: Strength design is different
Fire pump :(Shut off head + 50m) x 2
5: Seal form is different
Fire pump : Soft packing in principle